Portal vein pulsatility: An important sonographic tool assessment of systemic congestion for critical ill patients

World J Cardiol. 2024 May 26;16(5):221-225. doi: 10.4330/wjc.v16.i5.221.

Abstract

In this editorial we comment on the article by Kuwahara et al, published in the recent issue of the World Journal of Cardiology. In this interesting paper, the authors showed a correlation between portal vein pulsatility ratio, examined by bedside ultrasonography, and prognosis of hospitalized patients with acute heart failure. Systemic congestion is being notoriously underdetected in the acutely ill population with conventional methods like clinical examination, biomarkers, central venous pressure estimation and X-rays. However, congestion should be a key therapeutic target due to its deleterious effects to end organ function and subsequently patient prognosis. Doppler flow assessment of the abdominal veins is gaining popularity worldwide, as a valuable tool in estimating comprehensively congestion and giving a further insight into hemodynamics and patient management.

Keywords: Central venous pressure; Hemodynamics; Organ perfusion; Point of care ultrasound; Systemic congestion; Venous excess ultrasound.

Publication types

  • Editorial