The ring-down artifact
- PMID: 3882979
- DOI: 10.7863/jum.1985.4.1.21
The ring-down artifact
Abstract
"Ring-down" is an ultrasound artifact that appears as a solid streak or a series of parallel bands radiating away from abdominal gas collections. Using an in vitro system of bubbles in water or gelatin, it was found that the ring-down artifact originated from the center of a cluster of four bubbles (bubble tetrahedron), three on top and one nestled beneath. Entrapped between the bubbles is a horn- or bugle-shaped fluid collection that we theorize emits a continuous sound wave back to the transducer when struck by an ultrasound pulse. Electronic processing by the scanner converts this continuous sound wave into the series of bands seen in the ring-down artifact.
Similar articles
-
Searchlight phenomenon: a novel artifact of the gallbladder.J Med Ultrason (2001). 2016 Apr;43(2):219-25. doi: 10.1007/s10396-015-0697-2. Epub 2016 Jan 9. J Med Ultrason (2001). 2016. PMID: 26748504
-
Gas bubble motion artifact in MDCT.AJR Am J Roentgenol. 2008 Feb;190(2):294-9. doi: 10.2214/AJR.07.2702. AJR Am J Roentgenol. 2008. PMID: 18212212
-
Differentiation of acoustic shadowing due to calculi and gas collections.Radiology. 1980 May;135(2):399-403. doi: 10.1148/radiology.135.2.7367635. Radiology. 1980. PMID: 7367635
-
Characterization of acoustic droplet vaporization for control of bubble generation under flow conditions.Ultrasound Med Biol. 2014 Mar;40(3):551-61. doi: 10.1016/j.ultrasmedbio.2013.10.020. Epub 2014 Jan 13. Ultrasound Med Biol. 2014. PMID: 24433748
-
Contribution of mesenteric fat to unsatisfactory abdominal and pelvic ultrasonography.Radiology. 1981 Sep;140(3):773-6. doi: 10.1148/radiology.140.3.7280248. Radiology. 1981. PMID: 7280248
Cited by
-
Lung ultrasound in a nutshell. Lines, signs, some applications, and misconceptions from a radiologist's point of view.Pol J Radiol. 2023 Jun 21;88:e294-e310. doi: 10.5114/pjr.2023.128866. eCollection 2023. Pol J Radiol. 2023. PMID: 37404548 Free PMC article. Review.
-
Lung Ultrasound Artifacts Interpreted as Pathology Footprints.Diagnostics (Basel). 2023 Mar 16;13(6):1139. doi: 10.3390/diagnostics13061139. Diagnostics (Basel). 2023. PMID: 36980450 Free PMC article.
-
B-Lines Lung Ultrasonography Simulation Using Finite Element Method.Diagnostics (Basel). 2022 Nov 10;12(11):2751. doi: 10.3390/diagnostics12112751. Diagnostics (Basel). 2022. PMID: 36359594 Free PMC article.
-
State of the Art in Lung Ultrasound, Shifting from Qualitative to Quantitative Analyses.Ultrasound Med Biol. 2022 Dec;48(12):2398-2416. doi: 10.1016/j.ultrasmedbio.2022.07.007. Epub 2022 Sep 23. Ultrasound Med Biol. 2022. PMID: 36155147 Free PMC article. Review.
-
Unusual appearance of air in soft tissue on ultrasound.Clin Exp Emerg Med. 2022 Dec;9(4):380-382. doi: 10.15441/ceem.22.219. Epub 2022 Sep 27. Clin Exp Emerg Med. 2022. PMID: 36153878 Free PMC article. No abstract available.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources