Micro-Ring Resonator Assisted Photothermal Spectroscopy of Water Vapor

Sensors (Basel). 2024 Jun 6;24(11):3679. doi: 10.3390/s24113679.

Abstract

We demonstrated, for the first time, micro-ring resonator assisted photothermal spectroscopy measurement of a gas phase sample. The experiment used a telecoms wavelength probe laser that was coupled to a silicon nitride photonic integrated circuit using a fibre array. We excited the photothermal effect in the water vapor above the micro-ring using a 1395 nm diode laser. We measured the 1f and 2f wavelength modulation response versus excitation laser wavelength and verified the power scaling behaviour of the signal.

Keywords: integrated photonics; photothermal spectroscopy; refractive index sensing.