Ex Vivo Lenticule Customization for Stromal Lenticule Addition Keratoplasty

Invest Ophthalmol Vis Sci. 2024 Aug 1;65(10):9. doi: 10.1167/iovs.65.10.9.

Abstract

Purpose: The purpose of this study was to explore the optimal shape of customized lenticules for stromal lenticule addition keratoplasty (SLAK) for off-centered ectasia.

Methods: Two different methods to create ex vivo models of eccentric-keratoconus were investigated. Twelve human corneas were used to create model 1 by a hyperopic photorefractive keratectomy (PRK), and model 2 by masked phototherapeutic keratectomy (PTK) on the anterior corneal surface, whereas both types received myopic ablation of the posterior surface. Keratoconus models underwent a modified femtosecond laser (FSL) flap-cut to create stromal pockets. Sixteen human corneas underwent FSL dissection to obtain four lenticule types: type I (planar) and type II (negative) lenticules were used without modifications, whereas type III (customized-planar), and type IV (customized-negative) lenticules underwent further masked-PRK to obtain an asymmetric bow-tie shape. Topographic, aberrometric analysis, and anterior segment optical coherence tomography (AS-OCT) were performed in all recipient corneas before and after lenticule implantation.

Results: Keratoconus model was successfully reproduced. Tomographic analysis showed a significant inferiorly decentered corneal steepening with coherent stromal thinning. Model 2 reproduced better the curvature of real keratoconus. Lenticules type I implantation induced a homogeneous corneal thickening, type III produced higher thickening in the inferior half of the cornea. Type II determined a maximal peripheral pachymetric increase, with a gradual reduction toward the center, and type IV presented an asymmetric peripheral thickening. Topographic assessment showed a cone apex flattening in all cases, but it was significantly higher in types II and IV. Customized lenticules improved significantly corneal surface regularity regarding types I and II.

Conclusions: The approach of customizing lenticules by increasing their asymmetry and tailoring the re-shaping effects, may improve SLAK outcomes in eccentric keratoconus.

MeSH terms

  • Aberrometry
  • Adult
  • Corneal Stroma* / surgery
  • Corneal Stroma* / transplantation
  • Corneal Topography*
  • Corneal Transplantation / methods
  • Female
  • Humans
  • Keratoconus* / physiopathology
  • Keratoconus* / surgery
  • Lasers, Excimer / therapeutic use
  • Male
  • Middle Aged
  • Photorefractive Keratectomy* / methods
  • Refraction, Ocular / physiology
  • Surgical Flaps
  • Tomography, Optical Coherence*