Comparative Evaluation of Commercial Test Kits Cleared for Use in Modified Two-Tiered Testing Algorithms for Serodiagnosis of Lyme Disease

J Infect Dis. 2024 Aug 14;230(Supplement_1):S76-S81. doi: 10.1093/infdis/jiae229.

Abstract

Background: Modified 2-tiered testing (MTTT) for Lyme disease utilizes automatable, high throughput immunoassays (AHTIs) in both tiers without involving western immunoblots, offering performance and practical advantages over standard 2-tiered testing (STTT; first-tier AHTI followed by immunoglobulin M (IgM) and immunoglobulin G (IgG) western immunoblots). For MTTT, Centers for Disease Control and Prevention recommends using AHTI test kits that have been cleared by Food and Drug Administration (FDA) specifically for this intended use. We evaluated performance of FDA-cleared MTTT commercial test kits from 3 manufacturers by comparing with STTT results.

Methods: We performed MTTT (total antibody AHTI with reflex to separate IgM and IgG AHTIs) using test kits from Diasorin, Gold Standard Diagnostics (GSD), and Zeus Scientific on 382 excess serum samples submitted to the clinical laboratory for routine Lyme disease serologic testing in July 2018, measuring agreement between MTTT and STTT using the κ statistic.

Results: Overall agreement with STTT was 0.87 (95% confidence interval [CI], .77-.97) using Diasorin assays (almost perfect agreement), 0.80 (95% CI, .68-.93) using GSD assays (substantial agreement) and 0.79 (95% CI, .68-.90) using Zeus assays (substantial agreement). For detection of IgM reactivity, agreement between MTTT and STTT was 0.70 (.51-.90; substantial), 0.63 (95% CI, .44-.82; substantial) and 0.56 (95% CI, .38-.73; moderate), respectively. For detection of IgG reactivity, MTTT/STTT agreement was 0.73 (95% CI,.58-.88), 0.78 (95% CI, .62-.94), and 0.75 (95% CI, .60-.90), respectively (substantial agreement in all cases).

Conclusions: MTTT results obtained using commercial test kits from 3 different manufacturers had substantial to almost perfect agreement with STTT results overall and moderate to substantial agreement for IgM and IgG detection independently. Commercial MTTT tests can be used broadly for the diagnosis of Lyme disease.

Keywords: Borrelia burgdorferi; Lyme; antibody; diagnosis; serology.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Adult
  • Algorithms
  • Antibodies, Bacterial* / blood
  • Borrelia burgdorferi / immunology
  • Female
  • Humans
  • Immunoassay / methods
  • Immunoglobulin G* / blood
  • Immunoglobulin M* / blood
  • Lyme Disease* / blood
  • Lyme Disease* / diagnosis
  • Lyme Disease* / immunology
  • Middle Aged
  • Reagent Kits, Diagnostic* / standards
  • Sensitivity and Specificity
  • Serologic Tests* / methods
  • United States

Substances

  • Immunoglobulin G
  • Immunoglobulin M
  • Reagent Kits, Diagnostic
  • Antibodies, Bacterial

Grants and funding