Three-dimensional Analysis of Lifting Effects after High-intensity Focused Ultrasound (Ultraformer-MPT) across Seven Facial Aesthetic Units Considering SonoAnatomy

Plast Reconstr Surg Glob Open. 2024 Oct 4;12(10):e6203. doi: 10.1097/GOX.0000000000006203. eCollection 2024 Oct.

Abstract

Background: This investigation delves deep into the lifting degree for each area of noninvasive facial rejuvenation through high-intensity focused ultrasound (HIFU). The study meticulously examines the lifting effects of HIFU treatment across seven distinct facial aesthetic-units, using advanced three-dimensional scanner analysis.

Methods: The study examined a cohort of 50 patients treated with HIFU. Pre- and immediate posttreatment evaluations were conducted using three-dimensional scanner analysis, allowing for precise quantification of lifting effects across seven aesthetic units. Treatment protocols were tailored to leverage five cartridges with micropulsed mode options, optimizing outcomes based on sonographic anatomy.

Results: The forehead was lifted by 1.24 mm; crow's feet, 2.25; malar region, 2.46; posterior cheek, 3.40; jowl, 2.90; mandible, 3.09; and neck, 3.53.

Conclusions: The forehead showed a lift of 1.24 mm, attributed to the thin tissue requiring a cautious approach to avoid discomfort. A lift of 2.25 mm in the crow's feet area demonstrated the efficacy of HIFU in addressing fine lines and wrinkles. Significant lift of 2.47 mm in the malar region highlights HIFU's effectiveness in addressing mid-face laxity and restoring volume to the cheeks. The most substantial lift of 3.38 mm in the posterior cheek underscores targeted energy application for enhanced lifting and contouring. Notable lifting effect of 2.90 mm in the jowl area benefits sagging along the jawline, refining facial contour. Lift of 3.10 mm in the mandible shows improvement of lower facial laxity, defining the jawline. The highest lift of 3.55 mm in the neck region addresses laxity and sagging for a defined neck profile.