Diagnostic accuracy of [99mTc]-Tc-HYNIC-PSMA-11 SPECT/CT in differentiating tumor recurrence from post-treatment changes in glioblastoma

Neuroradiology. 2026 Jun;68(6):1699-1706. doi: 10.1007/s00234-026-04042-4. Epub 2026 May 28.

Abstract

Objective: This study aimed to evaluate the diagnostic accuracy of [99mTc]-Tc-HYNIC-PSMA-11 SPECT/CT in differentiating glioblastoma recurrence from post-treatment changes, comparing both visual and quantitative parameters with follow-up MRI as the reference standard.

Methods: In this cross-sectional study, 31 lesions with suspected glioblastoma recurrence underwent [99mTc]-Tc-HYNIC-PSMA-11 SPECT/CT imaging. PSMA uptake was assessed visually (0: no uptake, 1: mild, 2: moderate, 3: severe) and quantitatively using the tumor-to-background ratio (TBR). Diagnostic performance was evaluated through ROC analysis, sensitivity, specificity, and area under the curve (AUC) comparisons.

Results: Among the 30 patients with 31 lesions (70% male, mean age 46 years), initial MRI identified recurrence in 38.71% (n = 12), no recurrence in 35.48% (n = 11), and was indeterminate in 25.81% (n = 8) of lesions. Follow-up MRI and other clinical data confirmed recurrence in 58.06% (n = 18) and no recurrence in 41.94% (n = 13). Quantitative SPECT/CT analysis revealed a mean TBR of 13.08 ± 12.09. Visual PSMA assessment demonstrated a sensitivity of 83% and specificity of 92% when considering moderate/high uptake as positive. TBR quantitative analysis showed excellent discrimination (AUC = 0.87), with an optimal threshold of 7.55 yielding 89% sensitivity and 91% specificity. Initial MRI had 100% sensitivity and 91.67% specificity when excluding indeterminate cases. For the 8 patients with indeterminate initial MRI, both visual and quantitative PSMA parameters showed 100% accuracy in predicting the final diagnosis.

Conclusion: [99mTc]-Tc-HYNIC-PSMA-11 SPECT/CT, particularly using quantitative TBR analysis, offers a reliable alternative to MRI for detecting GBM recurrence, especially in cases where MRI findings are equivocal.

Keywords: Diagnostic accuracy; Glioblastoma; MRI; PSMA SPECT/CT; Recurrence.

MeSH terms

  • Adult
  • Aged
  • Brain Neoplasms* / diagnostic imaging
  • Brain Neoplasms* / pathology
  • Brain Neoplasms* / therapy
  • Cross-Sectional Studies
  • Diagnosis, Differential
  • Female
  • Gallium Radioisotopes
  • Glioblastoma* / diagnostic imaging
  • Glioblastoma* / pathology
  • Glioblastoma* / therapy
  • Humans
  • Hydrazines
  • Magnetic Resonance Imaging
  • Male
  • Middle Aged
  • Neoplasm Recurrence, Local* / diagnostic imaging
  • Neoplasm Recurrence, Local* / pathology
  • Octreotide / analogs & derivatives
  • Organotechnetium Compounds*
  • Radiopharmaceuticals
  • Sensitivity and Specificity
  • Single Photon Emission Computed Tomography Computed Tomography* / methods

Substances

  • Organotechnetium Compounds
  • Radiopharmaceuticals
  • Hydrazines
  • technetium Tc 99m hydrazinonicotinyl-Tyr(3)-octreotide
  • PSMA-11
  • Gallium Radioisotopes
  • Octreotide