Gastrointestinal and in vitro release of copper, cadmium, indium, mercury and zinc from conventional and copper-rich amalgams
- PMID: 6573763
- DOI: 10.1111/j.1600-0722.1983.tb00778.x
Gastrointestinal and in vitro release of copper, cadmium, indium, mercury and zinc from conventional and copper-rich amalgams
Abstract
Particles of a conventional lathe-cut, a spherical non-gamma 2 and a copper amalgam have been gastrointestinally administered to rats for the purpose of evaluation of the dissolution resistance. The animals were sacrificed after 20 hrs. The contents of copper, cadmium, indium, mercury and zinc in kidney, liver, lung or blood were measured using nuclear tracer techniques. From a copper amalgam an extreme release of copper was demonstrated. This study stimulates the clinical condition of elemental release from swallowed amalgam particles after amalgam insertion or after removal of old amalgam fillings. Specimens of the same types of amalgams were also exposed to artificial saliva for a period of 10 days. The amounts of copper and mercury released were measured with flame and flameless atomic absorption spectrophotometry respectively. The levels of copper and mercury released from the copper amalgam were approximately 50 times those of the two other amalgam types studied.
Similar articles
-
Metals in solution in mercury expressed from copper-rich dental amalgams.J Dent Res. 1982 Jan;61(1):30-2. doi: 10.1177/00220345820610010601. J Dent Res. 1982. PMID: 6948013 No abstract available.
-
Test of long-term corrosion of dental amalgams.Scand J Dent Res. 1986 Jun;94(3):253-8. doi: 10.1111/j.1600-0722.1986.tb01761.x. Scand J Dent Res. 1986. PMID: 3461546
-
Initial corrosion of amalgams in vitro.Scand J Dent Res. 1984 Apr;92(2):165-71. doi: 10.1111/j.1600-0722.1984.tb00874.x. Scand J Dent Res. 1984. PMID: 6585923
-
Metal release from dental biomaterials.Biomaterials. 1986 May;7(3):163-75. doi: 10.1016/0142-9612(86)90097-9. Biomaterials. 1986. PMID: 3521750 Review.
-
[Amalgam. III. Mercury release from amalgam restorations].Ned Tijdschr Tandheelkd. 1993 Feb;100(2):45-8. Ned Tijdschr Tandheelkd. 1993. PMID: 11822121 Review. Dutch.
Cited by 3 articles
-
Nuclear corrosion monitoring- : NCM-applied to biomaterials.Biol Trace Elem Res. 1987 Aug;13(1):319-31. doi: 10.1007/BF02796643. Biol Trace Elem Res. 1987. PMID: 24254687
-
The dental amalgam toxicity fear: a myth or actuality.Toxicol Int. 2012 May;19(2):81-8. doi: 10.4103/0971-6580.97191. Toxicol Int. 2012. PMID: 22778502 Free PMC article.
-
Dependence of kinetic variables in the short-term release of Hg2+, Cu2+ and Zn2+ ions into synthetic saliva from an high-copper dental amalgam.J Mater Sci Mater Med. 2007 Aug;18(8):1521-7. doi: 10.1007/s10856-007-0124-3. Epub 2007 Mar 27. J Mater Sci Mater Med. 2007. PMID: 17387592