Effect of microwave radiation on the beating rate of isolated frog hearts

Bioelectromagnetics. 1984;5(2):263-70. doi: 10.1002/bem.2250050213.

Abstract

One hundred and two isolated frog hearts were divided into ten groups and placed individually in a waveguide filled with Ringer's solution and exposed to 2,450-MHz CW radiation at 2 and 8.55 W/kg. Heart rate was recorded using one of the following methods: 3-M KCl glass electrode, ultrasound probe, tension transducer, Ringer's solution glass electrode, and a metal wire inserted in the Ringer's solution electrode. An accelerated decrease of heart rate was observed only in those groups recorded using the 3-M KCl electrode and the metal wire Ringer's solution electrode. No effect was found in the other groups. These results indicate that bradycardia in isolated hearts could be caused by electrode artifacts resulting from the intensification of electromagnetic fields.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Bradycardia / etiology
  • Electrodes / adverse effects
  • Heart Rate / radiation effects*
  • In Vitro Techniques
  • Microwaves*
  • Ranidae