Retrospective estimation and correction of physiological fluctuation in functional MRI
- PMID: 7476079
- DOI: 10.1002/mrm.1910340211
Retrospective estimation and correction of physiological fluctuation in functional MRI
Abstract
Image-to-image fluctuation due to physiological motion is a major limitation to the accurate detection of neuronal activity with functional MRI. In this paper, a new and general technique for the estimation and compensation of the physiological effects is presented. By simultaneously monitoring the respiration and heart beat during the acquisition of imaging data, and retrospectively synchronizing the imaging data with physiological activity, physiological effects are estimated and removed. This technique does not rely on the periodicity of the respiration or the heart beat, does not affect the signal changes arising from neuronal activation, and is beneficial to images acquired with any speed. Experimental studies performed with FLASH and EPI sequences have demonstrated that the new technique is effective in reducing physiological fluctuation and improving the sensitivity of functional MRI and is generally applicable.
Similar articles
-
Retrospective estimation and correction of physiological artifacts in fMRI by direct extraction of physiological activity from MR data.Magn Reson Med. 1996 Mar;35(3):290-8. doi: 10.1002/mrm.1910350305. Magn Reson Med. 1996. PMID: 8699939
-
Correction of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging.Magn Reson Med. 2002 Feb;47(2):344-53. doi: 10.1002/mrm.10065. Magn Reson Med. 2002. PMID: 11810679
-
Combination of BOLD-fMRI and VEP recordings for spin-echo MRI detection of primary magnetic effects caused by neuronal currents.Magn Reson Imaging. 2004 Dec;22(10):1429-40. doi: 10.1016/j.mri.2004.10.009. Magn Reson Imaging. 2004. PMID: 15707792
-
Reduction of signal fluctuation in functional MRI using navigator echoes.Magn Reson Med. 1994 May;31(5):495-503. doi: 10.1002/mrm.1910310505. Magn Reson Med. 1994. PMID: 8015402
-
Fiber-optic sensors for monitoring patient physiological parameters: a review of applicable technologies and relevance to use during magnetic resonance imaging procedures.J Biomed Opt. 2015 Jan;20(1):010901. doi: 10.1117/1.JBO.20.1.010901. J Biomed Opt. 2015. PMID: 25594625 Review.
Cited by
-
fMRI studies evaluating central respiratory control in humans.Front Neural Circuits. 2022 Sep 23;16:982963. doi: 10.3389/fncir.2022.982963. eCollection 2022. Front Neural Circuits. 2022. PMID: 36213203 Free PMC article. Review.
-
Brain-computer interfaces increase whole-brain signal to noise.Proc Natl Acad Sci U S A. 2013 Aug 13;110(33):13630-5. doi: 10.1073/pnas.1210738110. Epub 2013 Jul 30. Proc Natl Acad Sci U S A. 2013. PMID: 23901117 Free PMC article.
-
[Functional magnetic resonance imaging with ultra-high fields].Radiologe. 2010 Feb;50(2):144-51. doi: 10.1007/s00117-009-1897-9. Radiologe. 2010. PMID: 20012005 Review. German.
-
Timing of cortical activation: a latency-resolved event-related functional MR imaging study.AJNR Am J Neuroradiol. 2003 Nov-Dec;24(10):1967-74. AJNR Am J Neuroradiol. 2003. PMID: 14625218 Free PMC article.
-
A Descriptive Review of the Impact of Patient Motion in Early Childhood Resting-State Functional Magnetic Resonance Imaging.Diagnostics (Basel). 2022 Apr 20;12(5):1032. doi: 10.3390/diagnostics12051032. Diagnostics (Basel). 2022. PMID: 35626188 Free PMC article. Review.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical