Assessment of living renal donors with spiral CT

Radiology. 1995 May;195(2):457-62. doi: 10.1148/radiology.195.2.7724766.

Abstract

Purpose: To determine whether spiral computed tomography (CT) can be used to evaluate potential living renal donors.

Materials and methods: Twelve potential living renal donors underwent spiral CT and conventional arteriography. CT angiography was performed with 30-second spiral acquisition during injection of 150 mL of nonionic iodinated contrast material into an antecubital vein at 5 mL/sec. Five minutes after injection, a frontal abdominal scout projection was obtained to assess the renal collecting system. Results of blinded interpretations of axial CT angiograms, three-dimensional CT angiograms, and conventional arteriograms were correlated with intraoperative findings in 11 cases.

Results: Axial and three-dimensional CT angiography were 100% sensitive for identifying seven accessory renal arteries and 14% and 93% sensitive for identifying five prehilar renal artery branches. Renal venous anomalies were confirmed in three patients at surgery. Operative management changed in four of 11 patients who underwent donor nephrectomy.

Conclusion: Spiral CT holds promise as a single examination for anatomic assessment of living renal donors.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Angiography / methods*
  • Female
  • Humans
  • Image Processing, Computer-Assisted*
  • Iopamidol
  • Kidney Transplantation*
  • Male
  • Preoperative Care
  • Renal Artery / abnormalities
  • Renal Artery / diagnostic imaging*
  • Renal Veins / abnormalities
  • Renal Veins / diagnostic imaging*
  • Sensitivity and Specificity
  • Tissue Donors
  • Tomography, X-Ray Computed / methods*
  • Urography / methods

Substances

  • Iopamidol