Low and high frequency stimulation tests to characterize the effects of edrophonium on vecuronium-induced neuromuscular block

Br J Anaesth. 1995 Jan;74(1):12-5. doi: 10.1093/bja/74.1.12.

Abstract

We recorded adductor pollicis mechanical activity in response to low (0.1 and 2 Hz) and high (50 and 100 Hz) frequency stimulation 15 min after edrophonium 250, 500 and 1000 micrograms kg-1, given to antagonize vecuronium-induced block at 10, 25 and 50% pre-reversal twitch height. We studied 54 ASA class I and II anaesthetized (methohexitone, fentanyl, nitrous oxide) young adult patients allocated randomly to nine groups of six patients each. The greater sensitivity of train-of four (TOF) ratio and residual force after 100-Hz, 5-s tetanic stimulation (RF100) to residual deficit allowed discrimination more readily between the effects of edrophonium dose and pre-reversal twitch height (P < 0.001, two-way analysis of variance). The highest reversal scores (approximately 0.9 TOF ratio and 0.6 RF100) were obtained when edrophonium 500-1000 mg kg-1 was given at 50% twitch height (P < 0.05, Duncan's test).

Publication types

  • Clinical Trial
  • Comparative Study
  • Randomized Controlled Trial

MeSH terms

  • Adolescent
  • Adult
  • Dose-Response Relationship, Drug
  • Edrophonium / pharmacology*
  • Humans
  • Middle Aged
  • Muscle Contraction / drug effects
  • Muscle Contraction / physiology
  • Nerve Block*
  • Neuromuscular Junction / drug effects*
  • Neuromuscular Junction / physiology
  • Synaptic Transmission
  • Transcutaneous Electric Nerve Stimulation*
  • Vecuronium Bromide / antagonists & inhibitors*

Substances

  • Edrophonium
  • Vecuronium Bromide