Multisite evaluation of four anti-HIV-1/HIV-2 enzyme immunoassays. Australian HIV Test Evaluation Group
- PMID: 7882108
Multisite evaluation of four anti-HIV-1/HIV-2 enzyme immunoassays. Australian HIV Test Evaluation Group
Abstract
The performance of four enzyme immunoassays, manufactured by Abbott, Diagnostics Pasteur, Genetic Systems, and Organon Teknika, for the combined detection of anti-human immunodeficiency virus type 1 (HIV-1) and anti-HIV-2, was examined in a multisite evaluation. The collaborative efforts of 7 Australian Red Cross Blood Transfusion and 12 Australian Public Health Laboratories minimized potential biases in data by providing large numbers of anti-HIV-1-negative and -positive samples. Sensitivity was estimated using samples that were positive for anti-HIV-1 from individuals known to be infected and seroconversion samples. Sensitivity estimates in the four assays were 99.71, 99.94, 99.49, and 99.68%, respectively. Specificity was measured using fresh, sequential blood donations and samples with previous false-positive reactions in other assays. Specificity estimates from blood donations were 99.92, 99.46, 99.67, and 99.85%, respectively. The data were analyzed further using the delta statistic, which distinguishes the performance of assays of similar sensitivity and specificity by providing a measure of how well results in a population of positive or negative samples are removed from the assay's cutoff value.
Similar articles
-
Performance evaluation of three automated human immunodeficiency virus antigen-antibody combination immunoassays.J Virol Methods. 2006 Apr;133(1):20-6. doi: 10.1016/j.jviromet.2005.10.013. Epub 2005 Nov 28. J Virol Methods. 2006. PMID: 16313975
-
[Specificity of a new test for detection of antibodies to HIV-1/-2 in blood donors].Infusionsther Transfusionsmed. 1996 Jun;23(3):133-7. Infusionsther Transfusionsmed. 1996. PMID: 8924748 German.
-
[Could saliva be used to detect HIV seroconversion?].Sante. 1997 Sep-Oct;7(5):303-7. Sante. 1997. PMID: 9480036 French.
-
[Current methods of immunological and genetic diagnosis of HIV infection (literature review)].Klin Lab Diagn. 1995 Sep-Oct;(5):12-6. Klin Lab Diagn. 1995. PMID: 7582764 Review. Russian. No abstract available.
-
Frequency, causes, and new challenges of indeterminate results in Western blot confirmatory testing for antibodies to human immunodeficiency virus.Clin Vaccine Immunol. 2007 Jun;14(6):649-59. doi: 10.1128/CVI.00393-06. Epub 2007 Apr 4. Clin Vaccine Immunol. 2007. PMID: 17409223 Free PMC article. Review. No abstract available.
Cited by
-
Detection of human immunodeficiency virus antibodies in oral fluids.Clin Diagn Lab Immunol. 1998 Jul;5(4):419-26. doi: 10.1128/CDLI.5.4.419-426.1998. Clin Diagn Lab Immunol. 1998. PMID: 9665942 Free PMC article. Review. No abstract available.
-
A simple whole-blood test for detecting antibodies to human immunodeficiency virus.Clin Diagn Lab Immunol. 1998 Mar;5(2):263-5. doi: 10.1128/CDLI.5.2.263-265.1998. Clin Diagn Lab Immunol. 1998. PMID: 9521156 Free PMC article.
-
Blood screening by nucleic acid amplification technology: current issues, future challenges.Mol Diagn. 2000 Mar;5(1):11-22. doi: 10.1007/BF03262018. Mol Diagn. 2000. PMID: 10837085
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical