Biomechanical concerns with fixed partial dentures involving implants
- PMID: 8004049
- DOI: 10.1097/00008505-199312000-00002
Biomechanical concerns with fixed partial dentures involving implants
Abstract
Nine biomechanical factors involved in the design and fabrication of fixed partial dentures incorporating implants are discussed, focusing upon the deleterious effects of leverage, torsion, occlusal overload, and poor oral hygiene. Areas of concern are cantilevers, pier abutments, excessive fixed spans, use and misuse of nonrigid connectors, off-axis loading, occlusal plane to implant height ratio, inadequate support, distribution, and mandibular flexion and torsion.
Similar articles
-
Microstrain around dental implants supporting fixed partial prostheses under axial and non-axial loading conditions, in vitro strain gauge analysis.J Craniofac Surg. 2013 Nov;24(6):e546-51. doi: 10.1097/SCS.0b013e31829ac83d. J Craniofac Surg. 2013. PMID: 24220463
-
Retrospective evaluation of complete-arch fixed partial dentures connecting teeth and implant abutments in patients with normal and reduced periodontal support.J Prosthet Dent. 2005 Oct;94(4):313-20. doi: 10.1016/j.prosdent.2005.08.007. J Prosthet Dent. 2005. PMID: 16198167
-
Cantilever and implant biomechanics: a review of the literature. Part 1.J Prosthodont. 1994 Mar;3(1):41-6. doi: 10.1111/j.1532-849x.1994.tb00124.x. J Prosthodont. 1994. PMID: 8061790 Review.
-
Finite element stress analysis of tooth-to-implant fixed partial denture designs.J Prosthodont. 1993 Jun;2(2):83-92. doi: 10.1111/j.1532-849x.1993.tb00388.x. J Prosthodont. 1993. PMID: 8242171
-
Root intrusion in tooth-implant combination cases.Implant Dent. 1993 SUM;2(2):79-85. doi: 10.1097/00008505-199305000-00002. Implant Dent. 1993. PMID: 8242016 Review.
Cited by
-
Median mandibular flexure-the unique physiological phenomenon of the mandible and its clinical significance in implant restoration.Front Bioeng Biotechnol. 2023 Sep 7;11:1238181. doi: 10.3389/fbioe.2023.1238181. eCollection 2023. Front Bioeng Biotechnol. 2023. PMID: 37744259 Free PMC article. Review.
-
The effect of mandibular flexure on the design of implant-supported fixed restorations of different facial types under two loading conditions by three-dimensional finite element analysis.Front Bioeng Biotechnol. 2022 Aug 29;10:928656. doi: 10.3389/fbioe.2022.928656. eCollection 2022. Front Bioeng Biotechnol. 2022. PMID: 36105608 Free PMC article.
-
A Comparative Evaluation of the Strain Transmitted through Prostheses on Implants with Two Different Macro-Structures and Connection during Insertion and Loading Phase: An In Vitro Study.Materials (Basel). 2022 Jul 16;15(14):4954. doi: 10.3390/ma15144954. Materials (Basel). 2022. PMID: 35888421 Free PMC article.
-
Survival rates of ultra-short (<6 mm) compared with short locking-taper implants supporting single crowns in posterior areas: A 5-year retrospective study.Clin Implant Dent Relat Res. 2021 Dec;23(6):904-919. doi: 10.1111/cid.13054. Epub 2021 Nov 18. Clin Implant Dent Relat Res. 2021. PMID: 34796619 Free PMC article.
-
Clinical outcomes of single implant supported crowns versus 3-unit implant-supported fixed dental prostheses in Dubai Health Authority: a retrospective study.BMC Oral Health. 2021 Apr 1;21(1):171. doi: 10.1186/s12903-021-01530-2. BMC Oral Health. 2021. PMID: 33794841 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources