Intracranial aneurysms: diagnostic accuracy of three-dimensional, Fourier transform, time-of-flight MR angiography

Radiology. 1994 Oct;193(1):181-6. doi: 10.1148/radiology.193.1.8090889.

Abstract

Purpose: To assess the accuracy of three-dimensional, Fourier transform, time-of-flight magnetic resonance (MR) angiography in the identification of intracranial aneurysms.

Materials and methods: MR angiograms of 126 patients (59 male and 67 female patients, aged 12-77 years) with various intracranial vascular lesions were evaluated. Seventy-eight aneurysms, including 60 less than 5 mm in diameter, in 61 patients were depicted at conventional angiography. Eight projection images, as well as one axial collapsed MR angiogram obtained with a maximum-intensity projection algorithm, were used for evaluation.

Results: Sensitivity for the five observers ranged from 58% to 68% (mean, 63%). Higher sensitivity was achieved for anterior communicating and middle cerebral artery aneurysms, while that for internal carotid artery aneurysms was poor. Sensitivities for small and medium aneurysms ranged from 50% to 60% (mean, 56%) and from 77% to 94% (mean, 86%), respectively.

Conclusion: MR angiography can depict intracranial aneurysms 5 mm or larger with good accuracy but is less useful for the identification of smaller aneurysms.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Algorithms
  • Carotid Artery Diseases / diagnosis
  • Carotid Artery Diseases / diagnostic imaging
  • Carotid Artery Diseases / epidemiology
  • Cerebral Angiography
  • Female
  • Fourier Analysis
  • Humans
  • Image Processing, Computer-Assisted
  • Intracranial Aneurysm / diagnosis*
  • Intracranial Aneurysm / diagnostic imaging
  • Intracranial Aneurysm / epidemiology
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Observer Variation
  • Retrospective Studies
  • Sensitivity and Specificity