Evaluation of direct bladder stimulation with stainless steel woven eye electrodes

J Urol. 1993 Dec;150(6):1990-6. doi: 10.1016/s0022-5347(17)35952-9.

Abstract

Encouraged by recent clinical reports of micturition induced in patients by direct bladder stimulation, we conducted a study of optimum methods of direct bladder stimulation. During surgery six male cats received eight large surface-area woven eye electrodes sutured to the bladder wall serosa, four on the bladder dome and four adjacent to the trigone area. Two additional small surface-area single knot electrodes were sutured in the trigone area. Suprapubic and intraperitoneal tubes were placed for pressure recording and bladder filling. Leg and pelvic floor EMG electrodes were also used for tethered recordings. One to eight weeks after surgery, optimum stimulation methods were evaluated as the animal freely moved about a urodynamic recording cage. Electrodes in the trigone region were more effective than electrodes on the dome and induced bladder contractions and voiding similar to spontaneously induced voiding with bladder filing. Large surface area, woven eye electrodes, composed of multistranded 316LVM stainless steel wire, were more effective than smaller surface area single knot electrodes. High stimulating frequencies (40 Hz) were better than lower frequencies (10 to 20 Hz), and a 1 millisecond pulse duration was optimal. Pulsing with stimulating currents from 10 to 25 mA induced effective bladder contractions with voiding when applied for 3 seconds. However, lower currents using longer stimulation periods were also effective. Bipolar electrodes with both electrodes on the bladder wall were superior to monopolar arrangements with the positive ground electrode along the animal's back. We concluded that in the able-bodied cat model, bladder contractile activity for micturition can be induced with direct bladder stimulation and with little discomfort. An effective stimulation protocol consists of capacitor-coupled monophasic pulses with large surface area bipolar electrodes in the trigone region. Stimulating parameters of 40 Hz, 1 msec., 10 to 25 mA applied for 3 seconds were optimal. In addition, based on corrosion resistance observations, the electrodes are quite suitable for long-term studies.

Publication types

  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Animals
  • Cats
  • Electric Stimulation Therapy / instrumentation
  • Electric Stimulation Therapy / methods*
  • Electrodes, Implanted
  • Equipment Design
  • Male
  • Stainless Steel
  • Urinary Bladder / innervation*
  • Urinary Bladder / physiology
  • Urinary Bladder, Neurogenic / therapy*
  • Urination / physiology
  • Urodynamics / physiology*

Substances

  • Stainless Steel