Interexaminer reliability of eight evaluative dimensions of lumbar segmental abnormality: Part II
- PMID: 8409784
Interexaminer reliability of eight evaluative dimensions of lumbar segmental abnormality: Part II
Abstract
Objective: The objectives of this study were to assess the interexaminer agreement of palpation for soft tissue and osseous pain along with visual observations in the lumbar spine. Second, the interexaminer agreement of dermothermograph and surface electromyographic (EMG) scans of the lumbar spine were assessed. Third, to perform these evaluations on symptomatic low back patients. Finally, the most reliable measurements were combined in a multidimensional index of segmental lumbar abnormality, which was assessed for interexaminer agreement.
Design: This is an interexaminer reliability study of commonly used palpatory and instrumentation procedures used to assess lumbar segmental abnormality.
Setting: This study was conducted at Pain Assessment and Rehabilitation Center (PARC) and the Center for Clinical Studies (CCS) at Northwestern College of Chiropractic.
Patients: The patients involved in this study were symptomatic at the time of examination. The patients were recruited from the CCS clinic and PARC.
Results: Palpation for osseous pain produced kappa coefficients ranging from .48-.90. Palpation for soft tissue pain produced kappa coefficients that ranged from .40-.79 and the kappas for visual observation ranged from .34-.84. The dermothermograph and surface EMG scanner were also assessed with the kappa coefficient for their reliability in assessing lumbar segmental abnormality. The kappa coefficients ranged from -.13 to .59 for the surface EMG and 0- .63 for the dermothermograph measurements. Intraclass correlation coefficients for the surface EMG measurements ranged from .20-.55 and the dermothermograph measurements ranged from .01-.55. Palpation for pain (osseous and soft tissue) and visual observation were included in the multidimensional index of abnormality. The interexaminer agreement of detecting a manipulable lesion was evaluated by designating a lesion present with a positive two out of three tests. Kappa coefficients for the multidimensional index of lumbar abnormality ranged from a low of .05 to a high of .52.
Conclusions: Palpation for pain (osseous and soft tissue) and visual observation produced good to excellent interexaminer agreement and were included in the multidimensional index of abnormality. The interexaminer agreement of surface EMG scans and dermothermograph measurements were poor and considered to be clinically unacceptable, thus were not included in the multidimensional index. Palpation for pain is the only spinal assessment procedure to show consistent reliability in a number of studies.
Comment in
-
Interexaminer reliability of eight evaluative dimensions of lumbar segmental abnormality: Part II.J Manipulative Physiol Ther. 1994 Sep;17(7):495-6. J Manipulative Physiol Ther. 1994. PMID: 7695713 No abstract available.
-
Interexaminer reliability of eight evaluative dimensions of lumbar segmental abnormality: Part II.J Manipulative Physiol Ther. 1994 May;17(4):263-6. J Manipulative Physiol Ther. 1994. PMID: 8046283 No abstract available.
Similar articles
-
Interexaminer reliability of eight evaluative dimensions of lumbar segmental abnormality.J Manipulative Physiol Ther. 1990 Oct;13(8):463-70. J Manipulative Physiol Ther. 1990. PMID: 2146357 Clinical Trial.
-
Interexaminer reliability of palpation for cervical spine tenderness.J Manipulative Physiol Ther. 1994 Nov-Dec;17(9):591-5. J Manipulative Physiol Ther. 1994. PMID: 7884328
-
Spinal palpation for lumbar segmental mobility and pain provocation: an interexaminer reliability study.J Manipulative Physiol Ther. 2008 Jul-Aug;31(6):465-73. doi: 10.1016/j.jmpt.2008.06.004. J Manipulative Physiol Ther. 2008. PMID: 18722203
-
The reliability of lumbar motion palpation.J Manipulative Physiol Ther. 1992 Oct;15(8):518-24. J Manipulative Physiol Ther. 1992. PMID: 1402412 Review.
-
A review of intraexaminer and interexaminer reliability of static spinal palpation: a literature synthesis.J Manipulative Physiol Ther. 2009 Jun;32(5):379-86. doi: 10.1016/j.jmpt.2009.04.010. J Manipulative Physiol Ther. 2009. PMID: 19539121 Review.
Cited by
-
Anterior superior iliac spine asymmetry assessment on a novel pelvic model: an investigation of accuracy and reliability.J Manipulative Physiol Ther. 2010 Jun;33(5):378-85. doi: 10.1016/j.jmpt.2010.05.005. J Manipulative Physiol Ther. 2010. PMID: 20605557 Free PMC article.
-
Review of methods used by chiropractors to determine the site for applying manipulation.Chiropr Man Therap. 2013 Oct 21;21(1):36. doi: 10.1186/2045-709X-21-36. Chiropr Man Therap. 2013. PMID: 24499598 Free PMC article.
-
Further comments on veterinary chiropractic.Can Vet J. 2000 Jul;41(7):518-9. Can Vet J. 2000. PMID: 10907574 Free PMC article. No abstract available.
-
A randomized, placebo-controlled double-blinded comparative clinical study of five over-the-counter non-pharmacological topical analgesics for myofascial pain: single session findings.Chiropr Man Therap. 2012 Mar 21;20:7. doi: 10.1186/2045-709X-20-7. Chiropr Man Therap. 2012. PMID: 22436614 Free PMC article.
-
A model for standardizing manipulation terminology in physical therapy practice.J Man Manip Ther. 2008;16(1):50-6. doi: 10.1179/106698108790818567. J Man Manip Ther. 2008. PMID: 19119385 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Medical