Damage of tracer erythropoietin results in erroneous estimation of concentration in mouse submaxillary gland

Exp Hematol. 1993 Feb;21(2):299-302.

Abstract

It has been previously reported that 1) plasma erythropoietin (Epo) titer during exposure to hypobaria is lower in nephrectomized rats and mice whose submaxillary glands (SMG) were either ablated or atrophied than in nephrectomized controls whose SMG were intact and 2) that the gland shows one of the highest levels of immunoreactive Epo (iEpo) in the body. The latter observation, however, was questioned recently when it was observed that SMG extracts degrade labeled Epo used as tracer antigen in the radioimmunoassay (RIA), thus giving invalid estimates of Epo. Since this interpretation was in turn questioned, the present study was conducted to obtain more information on the subject and make these conflicting points clear. Investigation of the reported/possible degradation of Epo by SMG homogenates was conducted via polyacrylamide gel electrophoresis followed by radioautography or by a RIA in solid phase in which there was no simultaneous incubation of the tracer antigen with the SMG homogenates. It was observed that 125I-labeled rhEpo was degraded when incubated with SMG homogenates. Degradation was rapid, being evident when incubation lasted 30 minutes, and occurred in the presence of a protease inhibitor. It showed a high degree of specificity since it did not occur when Epo was incubated with kidney homogenate or normal mouse serum. SMG homogenate did not degrade labeled thyrotrophic hormone and degraded alpha interferon (IFN-alpha) only partially. When estimates of iEpo in SMG homogenate were performed in conditions of simultaneous (SI-RIA) or nonsimultaneous (NSI-RIA) incubation of the homogenate with tracer Epo, it was observed that while estimates of Epo in plasma were similar in both types of RIA and somewhat higher in kidney homogenate in the SI-RIA than in the NSI-RIA, estimates of Epo in SMG were about 60 times higher in the former than in the latter. Therefore, it could be concluded that most of the Epo detected by standard RIA in SMG homogenate does not represent true Epo because of damage of tracer Epo which determines loss of the integrity of the RIA system.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Electrophoresis, Polyacrylamide Gel
  • Erythropoietin / analysis*
  • Erythropoietin / metabolism
  • Iodine Radioisotopes
  • Male
  • Mice
  • Radioimmunoassay
  • Submandibular Gland / chemistry*
  • Submandibular Gland / metabolism

Substances

  • Iodine Radioisotopes
  • Erythropoietin