Experimental and numerical investigation of the 3D SPECT photon detection kernel for non-uniform attenuating media

Phys Med Biol. 1996 Jul;41(7):1167-89. doi: 10.1088/0031-9155/41/7/007.

Abstract

Experimental tests for non-uniform attenuating media are performed to validate theoretical expressions for the photon detection kernel, obtained from a recently proposed analytical theory of photon propagation and detection for SPECT. The theoretical multi-dimensional integral expressions for the photon detection kernel, which are computed numerically, describe the probability that a photon emitted from a given source voxel will trigger detection of a photon at a particular projection pixel. The experiments were performed using a cylindrical water-filled phantom with large cylindrical air-filled inserts to simulate inhomogeneity of the medium. A point-like, a short thin cylindrical and a large cylindrical radiation source of 99Tcm were placed at various positions within the phantom. The values numerically calculated from the theoretical kernel expression are in very good agreement with the experimentally measured data. The significance of Compton-scattered photons in planar image formation is discussed and highlighted by these results. Using both experimental measurements and the calculated values obtained from the theory, the kernel's size is investigated. This is done by determining the square N x N pixel neighbourhood of the gamma camera that must be connected to a particular radiation source voxel to account for a specific fraction of all counts recorded at all camera pixels. It is shown that the kernel's size is primarily dependent upon the source position and the properties of the attenuating medium through Compton scattering events, with 3D depth-dependent collimator resolution playing an important but secondary role, at least for imaging situations involving parallel hole collimation. By considering small point-like sources within a non-uniform elliptical phantom, approximating the human thorax, it is demonstrated that on average a 12 cm x 12 cm area of the camera plane is required to collect 85% of the total count recorded. This is a significantly larger connectivity than the 3 cm x 3 cm area required if scattering contributions are ignored and only the 3D depth-dependent collimator resolution is considered.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Gamma Cameras
  • Humans
  • Models, Theoretical
  • Phantoms, Imaging*
  • Photons
  • Thorax
  • Tomography, Emission-Computed, Single-Photon*