Ingested foreign body associated with oral implant treatment: report of a case

Int J Oral Maxillofac Implants. 1996 Sep-Oct;11(5):679-81.

Abstract

Hazards of oral implant treatment include the inadvertent ingestion or inhalation of components or instruments dropped accidentally into the oropharynx. A case is reported of a swallowed screwdriver, and attention is drawn to the potentially serious consequences. Guidance is given on management. Inhalation of foreign bodies is an even more serious event. The importance of prevention is emphasized both from a medicolegal point of view and as a matter of proper patient care.

Publication types

  • Case Reports

MeSH terms

  • Colonoscopy
  • Deglutition*
  • Dental Implantation, Endosseous / instrumentation*
  • Digestive System*
  • Endoscopy, Gastrointestinal
  • Female
  • Foreign Bodies / etiology*
  • Foreign Bodies / prevention & control
  • Foreign Bodies / therapy
  • Humans
  • Ileum
  • Inhalation
  • Lung
  • Oropharynx