Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1996 Nov;81(5):1891-900.
doi: 10.1152/jappl.1996.81.5.1891.

Muscle fatigue and exhaustion during dynamic leg exercise in normoxia and hypobaric hypoxia

Affiliations
Free article
Clinical Trial

Muscle fatigue and exhaustion during dynamic leg exercise in normoxia and hypobaric hypoxia

C S Fulco et al. J Appl Physiol (1985). 1996 Nov.
Free article

Abstract

Using an exercise device that integrates maximal voluntary static contraction (MVC) of knee extensor muscles with dynamic knee extension, we compared progressive muscle fatigue, i.e., rate of decline in force-generating capacity, in normoxia (758 Torr) and hypobaric hypoxia (464 Torr). Eight healthy men performed exhaustive constant work rate knee extension (21 +/- 3 W, 79 +/- 2 and 87 +/- 2% of 1-leg knee extension O2 peak uptake for normoxia and hypobaria, respectively) from knee angles of 90-150 degrees at a rate of 1 Hz. MVC (90 degrees knee angle) was performed before dynamic exercise and during < or = 5-s pauses every 2 min of dynamic exercise. MVC force was 578 +/- 29 N in normoxia and 569 +/- 29 N in hypobaria before exercise and fell, at exhaustion, to similar levels (265 +/- 10 and 284 +/- 20 N for normoxia and hypobaria, respectively; P > 0.05) that were higher (P < 0.01) than peak force of constant work rate knee extension (98 +/- 10 N, 18 +/- 3% of MVC). Time to exhaustion was 56% shorter for hypobaria than for normoxia (19 +/- 5 vs. 43 +/- 7 min, respectively; P < 0.01), and rate of right leg MVC fall was nearly twofold greater for hypobaria than for normoxia (mean slope = -22.3 vs. -11.9 N/min, respectively; P < 0.05). With increasing duration of dynamic exercise for normoxia and hypobaria, integrated electromyographic activity during MVC fell progressively with MVC force, implying attenuated maximal muscle excitation. Exhaustion, per se, was postulated to related more closely to impaired shortening velocity than to failure of force-generating capacity.

PubMed Disclaimer

Similar articles

Cited by

Publication types