Determination of vinca alkaloids in human plasma by liquid chromatography/atmospheric pressure chemical ionization mass spectrometry

Cancer Chemother Pharmacol. 1997;39(4):286-90. doi: 10.1007/s002800050574.

Abstract

A sensitive assay was developed for the quantitation of vinblastine, desacetylvinblastine and vincristine using liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (LC-APCI-MS). Analyses were performed on an Ultrasphere C18 microbore column using ammonium acetate as mobile phase. The calibration curves were linear across the range of 0.51-4.00 ng/ml (0.63-4.93 nM) for vinblastine, 0.74-3.93 ng/ml (0.96-5.11 nM) for desacetylvinblastine and 0.30-3.95 ng/ml (0.36-4.79 nM) for vincristine. Vinca alkaloid concentrations were measured with an accuracy and precision within 11%. This assay could be implemented to determine the plasma concentrations for pharmacokinetic studies of vinblastine, desacetylvinblastine and vincristine in conjunction with clinical trials.

MeSH terms

  • Chromatography, Ion Exchange
  • Chromatography, Liquid / methods
  • Humans
  • Mass Spectrometry
  • Vinblastine / blood
  • Vinca Alkaloids / blood*
  • Vincristine / blood

Substances

  • Vinca Alkaloids
  • Vincristine
  • Vinblastine