Adaptive bone remodeling around oral implants under axial and nonaxial loading conditions in the dog mandible
- PMID: 9109272
Adaptive bone remodeling around oral implants under axial and nonaxial loading conditions in the dog mandible
Abstract
An experimental animal model is presented for the analysis of the influence of axial and nonaxial loading on bone remodeling around oral implants. Axial and nonaxial loading conditions were introduced by placing a bilaterally supported fixed partial prosthesis and a cantilever fixed partial prosthesis on two IMZ implants in the mandibles of beagle dogs. Quantitative and qualitative histologic analyses revealed different remodeling tendencies between the loading conditions. Axial loading induced a more uniform, histologically quiescent remodeling response that gradually decreased from the coronal aspect to the apex of the implant. Nonaxial loading elicited a more dynamic remodeling of the surrounding cortical and especially trabecular bone tissue.
Similar articles
-
Bone remodeling adjacent to Morse cone-connection implants with platform switch: a fluorescence study in the dog mandible.Int J Oral Maxillofac Implants. 2009 Mar-Apr;24(2):257-66. Int J Oral Maxillofac Implants. 2009. PMID: 19492641
-
Composite morphology of the bone and associated support-tissue interfaces to osseointegrated dental implants: TEM and HVEM analyses.Int J Oral Maxillofac Implants. 1997 Jul-Aug;12(4):443-53. Int J Oral Maxillofac Implants. 1997. PMID: 9274073
-
Histologic evaluation of immediate versus delayed placement of implants after tooth extraction.Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2001 Jul;92(1):17-22. doi: 10.1067/moe.2001.115464. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2001. PMID: 11458241
-
Influence of forces on peri-implant bone.Clin Oral Implants Res. 2006 Oct;17 Suppl 2:8-18. doi: 10.1111/j.1600-0501.2006.01360.x. Clin Oral Implants Res. 2006. PMID: 16968378 Review.
-
Clinical and experimental bone changes after intraosseous implantation.J Prosthet Dent. 1995 Jan;73(1):31-5. doi: 10.1016/s0022-3913(05)80269-0. J Prosthet Dent. 1995. PMID: 7699596 Review.
Cited by
-
Three-dimensional finite element analysis of stress distribution on short implants with different bone conditions and osseointegration rates.BMC Oral Health. 2023 Apr 15;23(1):220. doi: 10.1186/s12903-023-02945-9. BMC Oral Health. 2023. PMID: 37061667 Free PMC article.
-
The effect of mandibular flexure on the design of implant-supported fixed restorations of different facial types under two loading conditions by three-dimensional finite element analysis.Front Bioeng Biotechnol. 2022 Aug 29;10:928656. doi: 10.3389/fbioe.2022.928656. eCollection 2022. Front Bioeng Biotechnol. 2022. PMID: 36105608 Free PMC article.
-
Three-Dimensional Finite Element Investigation into Effects of Implant Thread Design and Loading Rate on Stress Distribution in Dental Implants and Anisotropic Bone.Materials (Basel). 2021 Nov 18;14(22):6974. doi: 10.3390/ma14226974. Materials (Basel). 2021. PMID: 34832374 Free PMC article.
-
A temporospatial histomorphometric analysis of bone density adjacent to acid-etched self-tapping dental implants with an external hexagon connection in the female baboon.Clin Oral Investig. 2022 Feb;26(2):2143-2154. doi: 10.1007/s00784-021-04195-x. Epub 2021 Sep 29. Clin Oral Investig. 2022. PMID: 34585261
-
Implant Bio-mechanics for Successful Implant Therapy: A Systematic Review.J Int Soc Prev Community Dent. 2020 Nov 24;10(6):700-714. doi: 10.4103/jispcd.JISPCD_138_20. eCollection 2020 Nov-Dec. J Int Soc Prev Community Dent. 2020. PMID: 33437702 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Miscellaneous