Suction cup/contact lens complications following penetrating keratoplasty
- PMID: 9474457
Suction cup/contact lens complications following penetrating keratoplasty
Abstract
Purpose: Rigid gas permeable (RGP) contact lenses facilitate visual rehabilitation in cases of high or irregular corneal astigmatism following penetrating keratoplasty. A variety of plunger-like suction cup devices are available to assist in the removal of these lenses.
Methods: We report three patients with serious complications associated with the use of a suction cup device for contact lens removal following penetrating keratoplasty.
Results: Two patients suffered corneal wound dehiscence following contact lens removal; one contact lens was removed by the patient's spouse and the other was removed by a trained technician. A third patient triggered a graft rejection, and ultimately, graft failure, after a vigorous attempt at lens removal.
Conclusions: Forces generated by suction cup devices during removal of RGP contact lenses are sufficient to cause significant trauma. Contact lenses with an apical clearance fit may augment these forces, with the potential for complications following penetrating keratoplasty.
Similar articles
-
Visual rehabilitation using mini-scleral contact lenses after penetrating keratoplasty.Arq Bras Oftalmol. 2017 Jan-Feb;80(1):17-20. doi: 10.5935/0004-2749.20170006. Arq Bras Oftalmol. 2017. PMID: 28380096
-
Contact lens manipulation of corneal topography after penetrating keratoplasty: a preliminary study.CLAO J. 1992 Jul;18(3):177-82. CLAO J. 1992. PMID: 1499125
-
Scleral contact lenses for visual rehabilitation after penetrating keratoplasty: long term outcomes.Cont Lens Anterior Eye. 2014 Jun;37(3):196-202. doi: 10.1016/j.clae.2013.11.001. Epub 2013 Dec 2. Cont Lens Anterior Eye. 2014. PMID: 24300196
-
Fitting contact lenses for visual rehabilitation after penetrating keratoplasty.Eye Contact Lens. 2004 Jan;30(1):31-3. doi: 10.1097/01.ICL.0000101488.84455.E6. Eye Contact Lens. 2004. PMID: 14722466
-
Topographic stability and safety of contact lens use after penetrating keratoplasty.CLAO J. 1996 Jan;22(1):64-9. CLAO J. 1996. PMID: 8835072
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical