Comparison of responses of base-specific Salmonella tester strains with the traditional strains for identifying mutagens: the results of a validation study
- PMID: 9539966
- DOI: 10.1016/s1383-5718(97)00172-1
Comparison of responses of base-specific Salmonella tester strains with the traditional strains for identifying mutagens: the results of a validation study
Abstract
The ability of a TA7000 series of Salmonella his- mutant tester strains to detect mutagens as classified by the traditional tester strains (TA100, TA98, TA1535, TA1537, TA97, TA102 and TA104) was evaluated using 30 coded chemicals, 5 of which were duplicates with different code numbers. The TA7000 series of tester strains were TA7001, TA7002, TA7003, TA7004, TA7005 and TA7006, each of which reverts by a specific base substitution. In addition, each chemical was tested in a mixture of the base-specific strains (the Mix), plus the traditional strains, TA98 and TA1537. A liquid version of the Salmonella mutagenicity assay was performed in microtiter plates to allow partial automation for increased throughput. The results were compared to those in the National Toxicology Program (NTP) database, which were obtained from the traditional strains in the preincubation assay. In the two strains common to both protocols, TA98 and TA1537, the agreement was 80% and 85%, respectively. When compared to the NTP results for TA100, the Mix gave a 72% concordance, while the addition of the frameshift tester strain, TA98, increased the agreement to 76%. The overall agreement on positive or negative classifications of mutagenicity was 88% for the 25 chemicals tested. There were three notable exceptions to the overall agreement. Benzaldehyde was detected as a mutagen in TA7005 in contrast to its classification as a non-mutagen in the NTP database. This does not necessarily contradict the NTP results because the base-specific strains may respond to different mutagens. Two weak mutagens in the NTP database, 1-chloro-2-propanol and isobutyl nitrite, were not detected as mutagens in the base-specific new strains in the liquid protocol. While there are a number of major differences in the two assays, it was concluded that the results from each procedure are comparable.
Similar articles
-
Mutagenicity of benzo[b]phenanthro[2,3-d]thiophene (BPT) and its metabolites in TA100 and base-specific tester strains (TA7001-TA7006) of Salmonella typhimurium: evidence of multiple pathways for the bioactivation of BPT.Mutat Res. 2004 Jan 12;545(1-2):11-21. doi: 10.1016/s0027-5107(03)00138-6. Mutat Res. 2004. PMID: 14698413
-
Detection and classification of mutagens: a set of base-specific Salmonella tester strains.Proc Natl Acad Sci U S A. 1994 Nov 22;91(24):11606-10. doi: 10.1073/pnas.91.24.11606. Proc Natl Acad Sci U S A. 1994. PMID: 7972111 Free PMC article.
-
Using base-specific Salmonella tester strains to characterize the types of mutation induced by benzidine and benzidine congeners after reductive metabolism.Food Chem Toxicol. 2001 Dec;39(12):1253-61. doi: 10.1016/s0278-6915(01)00072-2. Food Chem Toxicol. 2001. PMID: 11696399
-
SOS induction in Escherichia coli and Salmonella mutagenicity: a comparison using 330 compounds.Mutagenesis. 1994 May;9(3):205-24. doi: 10.1093/mutage/9.3.205. Mutagenesis. 1994. PMID: 7934961 Review.
-
Recommendations for the performance of bacterial mutation assays.Mutat Res. 1994 Jun;312(3):217-33. doi: 10.1016/0165-1161(94)90037-x. Mutat Res. 1994. PMID: 7514736 Review.
Cited by
-
Qualitative and quantitative assessment of genotoxins using SRRz lysis reporter under the control of a newly designed SOS responsive promoter in Escherichia coli.RSC Adv. 2019 Nov 4;9(61):35662-35670. doi: 10.1039/c9ra06202e. eCollection 2019 Oct 31. RSC Adv. 2019. PMID: 35528065 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
