Optimized detection of DNA point mutations by double gradient denaturing gradient gel electrophoresis

Clin Chem Lab Med. 1998 Dec;36(12):959-61. doi: 10.1515/CCLM.1998.165.

Abstract

Denaturing gradient gel electrophoresis displays the highest detection rate among mutation scanning methods. In classical denaturing gradient gel electrophoresis the denaturant gradient range and migration times vary for every amplicon to be scanned, greatly affecting the routine application of the method. As an alternative, we developed double gradient denaturing gradient gel electrophoresis where a gradient of pore size is superimposed over the denaturing one, allowing maintenance of the zone-sharpening effect even over prolonged time runs, and adoption of identical run time conditions for all fragments analyzed. Here double gradient denaturing gradient gel electrophoresis has been applied to the analysis of a number of point mutations and polymorphisms located in several exons of three different genes, the cystic fibrosis transmembrane conductance regulator, the beta-globin and the p53 genes.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Cystic Fibrosis Transmembrane Conductance Regulator / genetics
  • DNA / genetics*
  • Electrophoresis, Polyacrylamide Gel / methods*
  • Genes, p53
  • Globins / genetics
  • Humans
  • Point Mutation*

Substances

  • CFTR protein, human
  • Cystic Fibrosis Transmembrane Conductance Regulator
  • Globins
  • DNA