Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1998 1
2003 1
2004 4
2005 1
2006 2
2007 2
2008 2
2009 2
2010 3
2011 3
2012 3
2014 2
2015 2
2017 4
2018 1
2019 2
2020 1
2021 3
2022 1
2024 1

Text availability

Article attribute

Article type

Publication date

Search Results

38 results

Results by year

Filters applied: . Clear all
Page 1
The effects of locking inserts and overtorque on the mechanical properties of a large fragment locking compression plate.
Meyers KN, Achor TS, Prasarn ML, Ahn J, Khalsa K, Wellman DS, Lorich DG, Helfet DL. Meyers KN, et al. Among authors: lorich dg, helfet dl. J Exp Orthop. 2021 Nov 24;8(1):106. doi: 10.1186/s40634-021-00424-0. J Exp Orthop. 2021. PMID: 34817734 Free PMC article.
PURPOSE: The study was to determine the effect of locking hole inserts and their insertion torque on the fatigue life of a large fragment Locking Compression Plate (LCP) under bending forces. ...Within each working length, plates were tested without …
PURPOSE: The study was to determine the effect of locking hole inserts and their insertion torque on the fatigue life of a large frag …
Novel Treatment Options for the Surgical Management of Young Femoral Neck Fractures.
Levack AE, Gausden EB, Dvorzhinskiy A, Lorich DG, Helfet DL. Levack AE, et al. Among authors: lorich dg, helfet dl. J Orthop Trauma. 2019 Jan;33 Suppl 1(Suppl 1):S33-S37. doi: 10.1097/BOT.0000000000001368. J Orthop Trauma. 2019. PMID: 30540670 Free PMC article. Review.
The surgical technique and clinical examples for constructs involving multiple cannulated screws/Pauwels screw augmented with a fibular strut graft, as well as a novel fixed-angle locking plate with controlled dynamic compression, are presented....
The surgical technique and clinical examples for constructs involving multiple cannulated screws/Pauwels screw augmented with a fibular stru …
The effects of dual plating on the vascularity of the distal femur.
Rollick NC, Gadinsky NE, Klinger CE, Kubik JF, Dyke JP, Helfet DL, Wellman DS. Rollick NC, et al. Among authors: helfet dl. Bone Joint J. 2020 Apr;102-B(4):530-538. doi: 10.1302/0301-620X.102B4.BJJ-2019-1776. Bone Joint J. 2020. PMID: 32228080
A medial vascular pedicle was found dividing from the superficial femoral artery at a mean 12.7 cm (SD 1.7) proximal to the medial epicondyle and was undisrupted in the dual plating group. CONCLUSION: Lateral locking-plate application resulted in mean 21.2% r …
A medial vascular pedicle was found dividing from the superficial femoral artery at a mean 12.7 cm (SD 1.7) proximal to the medial epicondyl …
Surgical Technique: Treatment of Distal Humerus Nonunions.
Donders JCE, Lorich DG, Helfet DL, Kloen P. Donders JCE, et al. Among authors: lorich dg, helfet dl. HSS J. 2017 Oct;13(3):282-291. doi: 10.1007/s11420-017-9551-y. Epub 2017 Apr 12. HSS J. 2017. PMID: 28983223 Free PMC article.
We have now follow-up on 62 treated patients. METHODS: A few key steps are essential to obtain bone healing while regaining or preserving elbow motion. These include careful planning, extensile exposure, release of the ulnar nerve, capsular release and mobilization of the …
We have now follow-up on 62 treated patients. METHODS: A few key steps are essential to obtain bone healing while regaining or preser …
Rate of avascular necrosis following proximal humerus fractures treated with a lateral locking plate and endosteal implant.
Neviaser AS, Hettrich CM, Dines JS, Lorich DG. Neviaser AS, et al. Among authors: lorich dg. Arch Orthop Trauma Surg. 2011 Dec;131(12):1617-22. doi: 10.1007/s00402-011-1366-6. Epub 2011 Aug 4. Arch Orthop Trauma Surg. 2011. PMID: 21814772
A total of 34 patients with complex proximal humerus fractures were treated with a locking plate and endosteal implant through an anterolateral approach and followed for an average of 66 weeks to determine the rates of avascular necrosis. ...CONCLUSION: Use of the a …
A total of 34 patients with complex proximal humerus fractures were treated with a locking plate and endosteal implant through …
Surgical outcomes of dual-plate fixation for periprosthetic femur fractures around a stable hip arthroplasty stem.
Kubik JF, Bornes TD, Gausden EB, Klinger CE, Wellman DS, Helfet DL. Kubik JF, et al. Among authors: helfet dl. Arch Orthop Trauma Surg. 2022 Dec;142(12):3605-3611. doi: 10.1007/s00402-021-03950-9. Epub 2021 May 18. Arch Orthop Trauma Surg. 2022. PMID: 34003368
Multiple treatment methods exist to treat fractures surrounding stable hip arthroplasty implants including locking plate fixation, cable fixation, allograft augmentation, and revision arthroplasty. ...Our preferred fixation construct involves a lateral plate
Multiple treatment methods exist to treat fractures surrounding stable hip arthroplasty implants including locking plate fixat …
Has locked plating completely replaced conventional plating?
Gardner MJ, Helfet DL, Lorich DG. Gardner MJ, et al. Among authors: lorich dg, helfet dl. Am J Orthop (Belle Mead NJ). 2004 Sep;33(9):439-46. Am J Orthop (Belle Mead NJ). 2004. PMID: 15509108 Review.
The 2 main approaches to fracture plate fixation--compression plating and internal splinting--result in differing biomechanics and subsequent healing response patterns. A number of advantages to using the newer internal fixators have been described, but there are st …
The 2 main approaches to fracture plate fixation--compression plating and internal splinting--result in differing biomechanics …
Locked plating of the proximal humerus using an endosteal implant.
Hettrich CM, Neviaser A, Beamer BS, Paul O, Helfet DL, Lorich DG. Hettrich CM, et al. Among authors: lorich dg, helfet dl. J Orthop Trauma. 2012 Apr;26(4):212-5. doi: 10.1097/BOT.0b013e318243909c. J Orthop Trauma. 2012. PMID: 22337487 Clinical Trial.
Using the anterolateral acromial approach, a proximal humeral locking plate augmented with a medial endosteal implant (fibular allograft in 23 patients and semitubular plate in 4 patients) was used for fixation. ...CONCLUSIONS: Use of a medial endosteal impla …
Using the anterolateral acromial approach, a proximal humeral locking plate augmented with a medial endosteal implant (fibular …
Evaluation and management of proximal humerus fractures.
Khmelnitskaya E, Lamont LE, Taylor SA, Lorich DG, Dines DM, Dines JS. Khmelnitskaya E, et al. Among authors: lorich dg. Adv Orthop. 2012;2012:861598. doi: 10.1155/2012/861598. Epub 2012 Dec 18. Adv Orthop. 2012. PMID: 23316376 Free PMC article.
In the case of displaced fractures, when surgical intervention may be pursued, numerous constructs have been investigated. Of these, the proximal humerus locking plate is the most widely used. Arthroplasty is generally reserved for comminuted 4-part fractures, head- …
In the case of displaced fractures, when surgical intervention may be pursued, numerous constructs have been investigated. Of these, the pro …
Catastrophic failure after open reduction internal fixation of femoral neck fractures with a novel locking plate implant.
Berkes MB, Little MT, Lazaro LE, Cymerman RM, Helfet DL, Lorich DG. Berkes MB, et al. Among authors: lorich dg, helfet dl. J Orthop Trauma. 2012 Oct;26(10):e170-6. doi: 10.1097/BOT.0b013e31823b4cd1. J Orthop Trauma. 2012. PMID: 22430524
PATIENTS/PARTICIPANTS: Twenty-one femoral neck fractures treated with the posterolateral femoral locking plate (Synthes, Inc, Paoli, PA) were eligible for inclusion. ...INTERVENTION: ORIF of femoral neck fracture with the posterolateral femoral locking pla
PATIENTS/PARTICIPANTS: Twenty-one femoral neck fractures treated with the posterolateral femoral locking plate (Synthes, Inc, …
38 results