Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1984 1
1986 4
1987 1
1988 4
1989 2
1990 11
1991 3
1992 2
1993 6
1994 5
1995 5
1996 2
1997 4
1998 4
1999 12
2000 5
2001 4
2002 3
2003 4
2004 1
2006 2
2007 1
2010 1
2012 2
2013 2
2014 2
2016 2
2017 1
2018 1
2019 1
2020 1
2021 1
2024 1

Text availability

Article attribute

Article type

Publication date

Search Results

98 results

Results by year

Filters applied: . Clear all
The following terms were ignored: %, %
The following terms were not found in PubMed: 20Lamb
Page 1
Showing results for brain%20T.%20Lamb
Your search for Brian%20T.%20Lamb retrieved no results
MRI and MRS of the human brain at magnetic fields of 14T to 20T: Technical feasibility, safety, and neuroscience horizons.
Budinger TF, Bird MD. Budinger TF, et al. Neuroimage. 2018 Mar;168:509-531. doi: 10.1016/j.neuroimage.2017.01.067. Epub 2017 Feb 5. Neuroimage. 2018. PMID: 28179167 Review.
Where feasible, effects are quantified for magnetic fields beyond 7T with the conclusion that there are no foreseen barriers either in the technical or human safety aspects of brain MRI and MRS at fields up to 20T. This conclusion is conditioned on results of recomm …
Where feasible, effects are quantified for magnetic fields beyond 7T with the conclusion that there are no foreseen barriers either in the t …
Brain Tumor Imaging without Gadolinium-based Contrast Agents: Feasible or Fantasy?
Wamelink IJHG, Azizova A, Booth TC, Mutsaerts HJMM, Ogunleye A, Mankad K, Petr J, Barkhof F, Keil VC. Wamelink IJHG, et al. Radiology. 2024 Feb;310(2):e230793. doi: 10.1148/radiol.230793. Radiology. 2024. PMID: 38319162 Review.
Gadolinium-based contrast agents (GBCAs) form the cornerstone of current primary brain tumor MRI protocols at all stages of the patient journey. Though an imperfect measure of tumor grade, GBCAs are repeatedly used for diagnosis and monitoring. ...On the basis of the curre …
Gadolinium-based contrast agents (GBCAs) form the cornerstone of current primary brain tumor MRI protocols at all stages of the patie …
Clinical magnetic resonance spectroscopy of brain, heart, liver, kidney, and cancer. A quantitative approach.
Weiner MW, Hetherington H, Hubesch B, Karczmar G, Massie B, Maudsley A, Meyerhoff DJ, Sappey-Marinier D, Schaefer S, Twieg DB, et al. Weiner MW, et al. NMR Biomed. 1989 Dec;2(5-6):290-7. doi: 10.1002/nbm.1940020519. NMR Biomed. 1989. PMID: 2701809 Review.
In most cases, techniques to quantitate absolute molar concentrations of metabolites in various organs were used. In the brain, AIDS, chronic stroke, and white matter lesions were associated with alterations of brain 31P metabolites. ...The PME/PCr was greatly incre …
In most cases, techniques to quantitate absolute molar concentrations of metabolites in various organs were used. In the brain, AIDS, …
A systematic review and meta-analysis of the role of ABCC2 variants on drug response in patients with epilepsy.
Grover S, Kukreti R. Grover S, et al. Epilepsia. 2013 May;54(5):936-45. doi: 10.1111/epi.12132. Epub 2013 Mar 18. Epilepsia. 2013. PMID: 23506516 Free article. Review.
SIGNIFICANCE: In summary, the results of our meta-analysis indirectly suggests possible role of the ABCC2 transporter at the blood brain barrier in altered drug response in PWE. Further studies are warranted in different ethnic groups to investigate the effects of the ABCC …
SIGNIFICANCE: In summary, the results of our meta-analysis indirectly suggests possible role of the ABCC2 transporter at the blood brain
B-type (brain) natriuretic peptide and pruritus in hemodialysis patients.
Shimizu Y, Sonoda A, Nogi C, Ogushi Y, Kanda R, Yamaguchi S, Nohara N, Aoki T, Yamada K, Nakata J, Io H, Kurusu A, Hamada C, Horikoshi S, Tomino Y. Shimizu Y, et al. Int J Nephrol Renovasc Dis. 2014 Aug 25;7:329-35. doi: 10.2147/IJNRD.S65929. eCollection 2014. Int J Nephrol Renovasc Dis. 2014. PMID: 25187733 Free PMC article.
INTRODUCTION AND OBJECTIVE: While pruritus is a common complication in hemodialysis patients, the pathophysiological mechanisms remain obscure. Recently, B-type (brain) natriuretic peptide (BNP) has been defined as an itch-selective neuropeptide in pruriceptive neurons in …
INTRODUCTION AND OBJECTIVE: While pruritus is a common complication in hemodialysis patients, the pathophysiological mechanisms remain obscu …
Half-Fourier single-shot STEAM MRI.
Finsterbusch J, Frahm J. Finsterbusch J, et al. Magn Reson Med. 2002 Mar;47(3):611-5. doi: 10.1002/mrm.10090. Magn Reson Med. 2002. PMID: 11870850 Free article.
The present work investigates the use of half-Fourier phase encoding which weakens the flip angle constraint by reducing the number of necessary excitations. Single-shot STEAM MRI of the normal human brain at 2.0 T demonstrates that half-Fourier versions either reduce the …
The present work investigates the use of half-Fourier phase encoding which weakens the flip angle constraint by reducing the number of neces …
Combining chemical exchange saturation transfer and 1 H magnetic resonance spectroscopy for simultaneous determination of metabolite concentrations and effects of magnetization exchange.
Hoefemann M, Döring A, Fichtner ND, Kreis R. Hoefemann M, et al. Magn Reson Med. 2021 Apr;85(4):1766-1782. doi: 10.1002/mrm.28574. Epub 2020 Nov 5. Magn Reson Med. 2021. PMID: 33151011 Free PMC article.
The saturation parameters are adjustable to allow optimization of the saturation for a specific target. Data were collected in brain from 20 subjects in experiments with different B(1) -settings (0.4-2.0 T) on a 3T MR scanner. ...
The saturation parameters are adjustable to allow optimization of the saturation for a specific target. Data were collected in brain
Localized NMR spectroscopy in vivo. Progress and problems.
Frahm J, Michaelis T, Merboldt KD, Hänicke W, Gyngell ML, Chien D, Bruhn H. Frahm J, et al. NMR Biomed. 1989 Dec;2(5-6):188-95. doi: 10.1002/nbm.1940020504. NMR Biomed. 1989. PMID: 2641893
Metabolites in brain and muscle of normal human volunteers have been studied by localized 1H and 31P NMR spectroscopy in vivo. Localization was achieved by means of stimulated echo (STEAM) sequences for both water-suppressed 1H NMR (TE = 20 ms) and 31P NMR (TE = 3 ms). Vol …
Metabolites in brain and muscle of normal human volunteers have been studied by localized 1H and 31P NMR spectroscopy in vivo. Locali …
Spin echo 31P spectroscopic imaging in the human brain.
Maudsley AA, Twieg DB, Sappey-Marinier D, Hubesch B, Hugg JW, Matson GB, Weiner MW. Maudsley AA, et al. Magn Reson Med. 1990 May;14(2):415-22. doi: 10.1002/mrm.1910140227. Magn Reson Med. 1990. PMID: 2345522
Spectroscopic imaging of phosphorus metabolites in the human brain has been carried out with two data acquisition methods: by observation of the free induction decay (FID) signal and by a short spin echo sequence. ...
Spectroscopic imaging of phosphorus metabolites in the human brain has been carried out with two data acquisition methods: by observa …
98 results