Development of a method for quantification of toluene diisocyanate and methylenediphenyl diisocyanate migration from polyurethane foam sample surface to artificial sweat by HPLC-UV-MS

J Chromatogr B Analyt Technol Biomed Life Sci. 2020 Apr 1:1142:122027. doi: 10.1016/j.jchromb.2020.122027. Epub 2020 Feb 27.

Abstract

The US Environmental protection agency (EPA) has published guidance that includes test procedures for evaluating indoor exposure to chemicals from products. One of the test procedures represents the migration test for evaluating potential dermal exposure from home furniture. Such an evaluation involves the chemical measurement of the sweat which is currently unavailable in the literature. The objective of this project was to develop and validate an analytical method for quantification of migration of 4,4'-methylenediphenyl diisocyanate (MDI), 2,6-toluene diisocyanate (2,6-TDI) and 2,4-toluene diisocyanate (2,4-TDI) from a polyurethane (PU) flexible foam to artificial sweat that meets the recommendations of the EPA test protocol. Following the EPA protocol, six synthetic sweat solutions were prepared and used in evaluation of isocyanate recovery performance. The migration tests were conducted using five foam types that were chosen and supplied by PU foam manufacturers to represent the types most commonly found in commercial products, and with formulations anticipated to have the highest potential residual TDI or MDI. Migration tests were conducted using glass fiber filters (GFF) coated with 1-(2-methoxyphenyl)piperazine (1,2-MP) and analyzed using HPLC equipped with a UV detector for quantification and a MS detector to qualify peaks. The detection limits of the method were 0.002 µg/mL for 2,6-TDI, 0.011 µg/mL for 2,4-TDI, and 0.003 µg/mL for MDI. Quantification limits were 0.006 µg/mL, 0.037 µg/mL, and 0.010 µg/mL, respectively. The recovery tests on a Teflon surface for 5 of the 6 EPA-recommended synthetic sweat solutions indicate the recovery percentage was approximately 80% for diisocyanates. Recovery for the sixth sweat solution was low, approximately 30%. TDI and MDI migration was not observed when testing was conducted on foam samples.

Keywords: 1-(2-methoxyphenyl) piperazine; Artificial sweat; HPLC-UV; Isocyanate; Migration; Polyurethane.

MeSH terms

  • Air Pollutants, Occupational / adverse effects
  • Air Pollutants, Occupational / chemistry
  • Chromatography, High Pressure Liquid
  • Environmental Exposure / adverse effects
  • Environmental Monitoring
  • Humans
  • Isocyanates / adverse effects
  • Isocyanates / chemistry*
  • Movement
  • Paint / adverse effects*
  • Polyurethanes / chemistry*
  • Surface Properties
  • Sweat / chemistry*
  • Tandem Mass Spectrometry
  • Toluene 2,4-Diisocyanate / adverse effects
  • Toluene 2,4-Diisocyanate / chemistry*

Substances

  • Air Pollutants, Occupational
  • Isocyanates
  • Polyurethanes
  • Toluene 2,4-Diisocyanate
  • polyurethane foam
  • 4,4'-diphenylmethane diisocyanate