Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2014 1
2015 5
2016 10
2017 9
2018 8
2019 11
2020 8
2021 2
Text availability
Article attribute
Article type
Publication date

Search Results

51 results
Results by year
Filters applied: . Clear all
Page 1
Cervical Cancer Markers: Epigenetics and microRNAs.
Laengsri V, Kerdpin U, Plabplueng C, Treeratanapiboon L, Nuchnoi P. Laengsri V, et al. Lab Med. 2018 Mar 21;49(2):97-111. doi: 10.1093/labmed/lmx080. Lab Med. 2018. PMID: 29378033 Review.
Despite extensive attempts by researchers to solve the molecular mystery of CC, the mechanisms of its pathogenesis remain unclear. Tumor markers used in the clinical laboratory, such as squamous cell carcinoma (SCC), cancer antigen (CA)-125, and CA19-9, provide some help i …
Despite extensive attempts by researchers to solve the molecular mystery of CC, the mechanisms of its pathogenesis remain unclear. Tumor mar …
Clinical and laboratory update on the DEL variant.
Nuchnoi P, Thongbus J, Srisarin A, Kerdpin U, Prachayasittikul V. Nuchnoi P, et al. Lab Med. 2014 Fall;45(4):285-90. doi: 10.1309/LMTUZ00O7VFTGCEB. Lab Med. 2014. PMID: 25316658 Review.
This observation has prompted the need for genetic epidemiological and clinical data on the DEL variant in the development of DEL molecular diagnostic testing. This review highlights the molecular features of the DEL variant, the clinical consequences of DEL-blood t …
This observation has prompted the need for genetic epidemiological and clinical data on the DEL variant in the development of DEL mol …
Prevalence and Clinical Utility of "Incidental" Critical Values Resulting From Critical Care Laboratory Testing.
Grieme CV, Voss DR, Olson KE, Davis SR, Kulhavy J, Krasowski MD. Grieme CV, et al. Lab Med. 2016 Nov;47(4):338-349. doi: 10.1093/labmed/lmw044. Lab Med. 2016. PMID: 27708170
OBJECTIVE: Panels of clinical laboratory testing may generate "incidental" critical values from unordered parameters. ...Relative to the manual effort involved in care providers' notification and documentation of results, incidental critical values appear to have low cl
OBJECTIVE: Panels of clinical laboratory testing may generate "incidental" critical values from unordered parameters. ...Relative to …
Adoption of Evidence-Based Medicine in Clinical Laboratory Science: A Survey of the Prevalence of Systematic and Narrative Reviews.
Pearson LN, Schmidt RL. Pearson LN, et al. Lab Med. 2019 Jul 16;50(3):223-228. doi: 10.1093/labmed/lmy069. Lab Med. 2019. PMID: 30462251
BACKGROUND: Systematic reviews (SRs) play a critical role in evidence-based medicine. OBJECTIVE: To determine the publication trends of SRs in clinical laboratory science (CLS). METHODS: We searched Scopus to identify all reviews published in the top 20 CLS journals during …
BACKGROUND: Systematic reviews (SRs) play a critical role in evidence-based medicine. OBJECTIVE: To determine the publication trends of SRs …
Peritoneal and Pleural Fluid Chemistry Measurements Performed on Three Chemistry Platforms.
Adams A, Straseski JA, Lehman CM, Pearson LN. Adams A, et al. Lab Med. 2019 Apr 8;50(2):145-149. doi: 10.1093/labmed/lmy056. Lab Med. 2019. PMID: 30169773
BACKGROUND: Chemistry testing is requested for body fluid (BF) specimens despite the lack of assays approved by the US Food and Drug Administration (FDA). ...
BACKGROUND: Chemistry testing is requested for body fluid (BF) specimens despite the lack of assays approved by the US Food and Drug …
Analytical Performance of 10 High-Volume Clinical Chemistry Assays on the Alinity c System.
Krintus M, Fernandez JA, Chesters C, Colla R, Ford C, Frattolillo D, Köller U, Mairesse J, Jimenez DM, Motol J, Padmore K, Sharrod-Cole H, Sypniewska G. Krintus M, et al. Lab Med. 2019 Jan 1;50(1):e1-e8. doi: 10.1093/labmed/lmy053. Lab Med. 2019. PMID: 30247580
BACKGROUND: Early access for routine testing with the Alinity c clinical chemistry system (Abbot Laboratories) presented the opportunity to characterize the analytical performance of multiple analytes across clinical laboratories in Europe. METHODS: A total o …
BACKGROUND: Early access for routine testing with the Alinity c clinical chemistry system (Abbot Laboratories) presented the o …
Performance Characteristics and Clinical Value of the Lipoprotein-Associated Phospholipase A2 by an Enzymatic Kinetic Method.
Lu M, Lv L. Lu M, et al. Lab Med. 2019 Jul 16;50(3):273-278. doi: 10.1093/labmed/lmy086. Lab Med. 2019. PMID: 30770710
OBJECTIVE: To analyze the performance characteristics, stability, and clinical value of lipoprotein-associated phospholipase A2 (Lp-PLA2) using an enzymatic kinetic method. ...In the CHD group, high-lipid subgroups, and high-TC group, Lp-PLA2 was elevated, and correlation …
OBJECTIVE: To analyze the performance characteristics, stability, and clinical value of lipoprotein-associated phospholipase A2 (Lp-P …
Tacrolimus: A Review of Laboratory Detection Methods and Indications for Use.
Kalt DA. Kalt DA. Lab Med. 2017 Nov 8;48(4):e62-e65. doi: 10.1093/labmed/lmx056. Lab Med. 2017. PMID: 29096030 Review.
This literature review will discuss Tac metabolism and its role in preventing tissue and organ transplant rejection. A variety of detection techniques used in the clinical laboratory, including dried-blood-spot analysis, liquid chromatography-tandem mass spectrometry, and …
This literature review will discuss Tac metabolism and its role in preventing tissue and organ transplant rejection. A variety of detection …
Interference of M-protein on Thrombin Time Test: A Case Report.
Njegovan M, Margetić S, Tešija Kuna A, Đerek L, Ćelap I, Pavičić T, Čaržavec D, Gaćina P. Njegovan M, et al. Lab Med. 2020 Sep 1;51(5):545-549. doi: 10.1093/labmed/lmz103. Lab Med. 2020. PMID: 32053192
CONCLUSION: Unexpectedly altered results of screening coagulation tests without any appropriate clinical signs and symptoms in a patient without any anticoagulant therapy needs to be critically considered in the context of extended next diagnostic steps in order to clarify …
CONCLUSION: Unexpectedly altered results of screening coagulation tests without any appropriate clinical signs and symptoms in a pati …
51 results
You have reached the last page of results. A maximum of 10,000 results are available.
Jump to page