Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1985 1
1987 1
2018 2
2021 2
2022 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

6 results

Results by year

Filters applied: . Clear all
Your search was processed without automatic term mapping because it retrieved zero results.
Page 1
Standardized medical image registration for radiological identification of decedents based on paranasal sinuses.
Gascho D, Philipp H, Flach PM, Thali MJ, Kottner S. Gascho D, et al. J Forensic Leg Med. 2018 Feb;54:96-101. doi: 10.1016/j.jflm.2017.12.003. Epub 2018 Jan 10. J Forensic Leg Med. 2018. PMID: 29348074
Image registration software is frequently used in clinical radiology, e.g., for follow-up diagnosis. To a certain extent, the radiological identification of decedents (RadID) is comparable to a clinical follow-up diagnosis, in that two datasets from different dates are com …
Image registration software is frequently used in clinical radiology, e.g., for follow-up diagnosis. To a certain extent, the radiolo …
Time- and Site-Dependent Postmortem Redistribution of Antidepressants and Neuroleptics in Blood and Alternative Matrices.
Brockbals L, Staeheli SN, Gascho D, Ebert LC, Kraemer T, Steuer AE. Brockbals L, et al. J Anal Toxicol. 2021 Apr 12;45(4):356-367. doi: 10.1093/jat/bkaa092. J Anal Toxicol. 2021. PMID: 32856054
However, limitations of the current study (e.g., temperature-controlled storage of the bodies) could have led to an underestimation of occurring postmortem changes, hence, interpretation of postmortem results should always be conducted with care, considering PMR phenomena …
However, limitations of the current study (e.g., temperature-controlled storage of the bodies) could have led to an underestimation o …
Evaluation of ultrashort echo-time (UTE) and fast-field-echo (FRACTURE) sequences for skull bone visualization and fracture detection - A postmortem study.
Deininger-Czermak E, Euler A, Franckenberg S, Finkenstaedt T, Villefort C, Gascho D, Guggenberger R. Deininger-Czermak E, et al. J Neuroradiol. 2022 May;49(3):237-243. doi: 10.1016/j.neurad.2021.11.001. Epub 2021 Nov 7. J Neuroradiol. 2022. PMID: 34758365 Free article.
CONCLUSIONS: Both MRI sequences may provide an alternative e.g. for surgical planning or follow up exams of the osseous neurocranium; although, at the skull base and viscerocranium bone visualization with MRI bone imaging sequences perform inferior to CT standard imaging.. …
CONCLUSIONS: Both MRI sequences may provide an alternative e.g. for surgical planning or follow up exams of the osseous neurocranium; …
Retained bullets in the head on computed tomography - Get the most out of iterative metal artifact reduction.
Berger F, Niemann T, Kubik-Huch RA, Richter H, Thali MJ, Gascho D. Berger F, et al. Eur J Radiol. 2018 Jun;103:124-130. doi: 10.1016/j.ejrad.2018.04.019. Epub 2018 Apr 22. Eur J Radiol. 2018. PMID: 29803377
To reduce metallic artifacts from medical implants on CT, special algorithms have been developed, e.g., iterative metal artifact reduction (iMAR). The aim of this prospective study was to evaluate the application of iMAR in cases of retained bullets. ...CONCLUSION: The app …
To reduce metallic artifacts from medical implants on CT, special algorithms have been developed, e.g., iterative metal artifact redu …
The effect of an increase in heart rate on remote myocardial blood flow in a two vessel coronary stenosis-occlusion model.
Gascho JA, Mahanes M, Beller GA. Gascho JA, et al. Can J Cardiol. 1987 Apr;3(3):148-53. Can J Cardiol. 1987. PMID: 3594295
In the presence of a left circumflex coronary artery stenosis (gradient 32 +/- 5 mmHg [x +/- SEM]) and an unstenosed left anterior descending coronary artery a pacing-induced rise in heart rate (22 +/- 1 beats/min) increased epicardial flow to the posterior wall supplied by the l …
In the presence of a left circumflex coronary artery stenosis (gradient 32 +/- 5 mmHg [x +/- SEM]) and an unstenosed left anterior descendin …
Effects of nitroglycerin-induced hypotension on myocardial blood flow in a two vessel occlusion-stenosis anesthetized canine model.
Gascho JA, Mahanes MS, Flanagan TL, Beller GA. Gascho JA, et al. J Am Coll Cardiol. 1985 Oct;6(4):856-63. doi: 10.1016/s0735-1097(85)80495-2. J Am Coll Cardiol. 1985. PMID: 3928728 Free article.
The infusion of intravenous nitroglycerin in the presence of a left circumflex stenosis (gradient 31 +/- 3 mm Hg) reduced systolic aortic and distal circumflex pressure to 98 +/- 2 (p = 0.001) and 71 +/- 4 mm Hg (p = 0.001), respectively, and lowered remote circumflex bed endocar …
The infusion of intravenous nitroglycerin in the presence of a left circumflex stenosis (gradient 31 +/- 3 mm Hg) reduced systolic aortic an …