Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2010 1
2012 1
2015 1
2016 1
2021 1
2022 1
2023 1
2024 1

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

8 results

Results by year

Filters applied: . Clear all
Page 1
Efficient Removal of Antimony(V) from Antimony Mine Wastewater by Micrometer Zero-Valent Iron.
Gan S, Meng Y, Lin Z, Zheng C, Zhu A, Ganjidoust H, Ayati B, Huo A. Gan S, et al. Langmuir. 2023 Oct 24;39(42):14945-14957. doi: 10.1021/acs.langmuir.3c01787. Epub 2023 Oct 10. Langmuir. 2023. PMID: 37814856
The results demonstrate that mZVI can reduce Sb(V) concentration in the mine wastewater from 3875.7 mug/L to below the drinking water standard of 5 mug/L within 2 h. Adding a small amount of mZVI every 30 min helps to maintain a high removal rate. ...
The results demonstrate that mZVI can reduce Sb(V) concentration in the mine wastewater from 3875.7 mug/L to below the drinking water standa …
MBBR system performance improvement for petroleum hydrocarbon removal using modified media with activated carbon.
Sayyahzadeh AH, Ganjidoust H, Ayati B. Sayyahzadeh AH, et al. Water Sci Technol. 2016;73(9):2275-83. doi: 10.2166/wst.2016.013. Water Sci Technol. 2016. PMID: 27148731
The analysis of results estimated the optimal values of HRT, MFR, and ACC used in the media between the studied levels, being equal to 22 h, 50%, and 7.5 g/L, respectively. Under these conditions, total petroleum hydrocarbons removal efficiencies for MBBR systems using Bee …
The analysis of results estimated the optimal values of HRT, MFR, and ACC used in the media between the studied levels, being equal to 22 …
Application of concrete surfaces as novel substrate for immobilization of TiO2 nano powder in photocatalytic treatment of phenolic water.
Delnavaz M, Ayati B, Ganjidoust H, Sanjabi S. Delnavaz M, et al. J Environ Health Sci Eng. 2015 Aug 4;13:58. doi: 10.1186/s40201-015-0214-y. eCollection 2015. J Environ Health Sci Eng. 2015. PMID: 26244097 Free PMC article.
FINDINGS: The removal efficiency of photocatalytic process in 4 h irradiation time and phenol concentration ranges of 25-500 mg/L was more than 80 %. ...
FINDINGS: The removal efficiency of photocatalytic process in 4 h irradiation time and phenol concentration ranges of 25-500 mg/L was …
Prediction of moving bed biofilm reactor (MBBR) performance for the treatment of aniline using artificial neural networks (ANN).
Delnavaz M, Ayati B, Ganjidoust H. Delnavaz M, et al. J Hazard Mater. 2010 Jul 15;179(1-3):769-75. doi: 10.1016/j.jhazmat.2010.03.069. Epub 2010 Mar 23. J Hazard Mater. 2010. PMID: 20399558
Efficiency evaluation of the reactors was obtained at different retention time (RT) of 8, 24, 48 and 72 h with an influent COD from 100 to 4000 mg/L. Exploratory data analysis was used to detect relationships between the data and dependent evaluated one. ...
Efficiency evaluation of the reactors was obtained at different retention time (RT) of 8, 24, 48 and 72 h with an influent COD from 1 …
Cultivation of aerobic granules in a novel configuration of sequencing batch airlift reactor.
Rezaei LS, Ayati B, Ganjidoust H. Rezaei LS, et al. Environ Technol. 2012 Oct-Nov;33(19-21):2273-80. doi: 10.1080/09593330.2012.665490. Environ Technol. 2012. PMID: 23393968
Comparing these two systems, the SBAR has excellent mixing condition, but due to a high height-to-diameter ratio (H/D), there is no performance capability at full scale at the present time. This research examined a novel configuration of SBAR at laboratory scale (with a bo …
Comparing these two systems, the SBAR has excellent mixing condition, but due to a high height-to-diameter ratio (H/D), there is no p …