Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Edit custom filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2007 1
2009 1
2010 2
2015 1
2016 1
2017 2
2019 1
2020 3
2021 1
2022 1
2023 1
2024 1
2025 1
2026 0

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

14 results

Results by year

Filters applied: . Clear all
Page 1
Sedentary Behavior among National Elite Rowers during Off-Training-A Pilot Study.
Sperlich B, Becker M, Hotho A, Wallmann-Sperlich B, Sareban M, Winkert K, Steinacker JM, Treff G. Sperlich B, et al. Front Physiol. 2017 Sep 20;8:655. doi: 10.3389/fphys.2017.00655. eCollection 2017. Front Physiol. 2017. PMID: 28979208 Free PMC article.
The average sedentary time was 11.63 1.25 h per day during the week and 12.49 1.10 h per day on the weekend, with a tendency to be higher on the weekend compared to weekdays (p = 0.06; d = 0.73). The average time in light, moderate and vigorous PA during the wee …
The average sedentary time was 11.63 1.25 h per day during the week and 12.49 1.10 h per day on the weekend, with a tenden …
Effects of acetazolamide on pulmonary artery pressure and prevention of high-altitude pulmonary edema after rapid active ascent to 4,559 m.
Berger MM, Sareban M, Schiefer LM, Swenson KE, Treff F, Schäfer L, Schmidt P, Schimke MM, Paar M, Niebauer J, Cogo A, Kriemler S, Schwery S, Pickerodt PA, Mayer B, Bärtsch P, Swenson ER. Berger MM, et al. J Appl Physiol (1985). 2022 Jun 1;132(6):1361-1369. doi: 10.1152/japplphysiol.00806.2021. Epub 2022 May 5. J Appl Physiol (1985). 2022. PMID: 35511718 Free article. Clinical Trial.
Thirteen healthy, nonacclimatized lowlanders with a history of HAPE ascended (<22 h) from 1,130 to 4,559 m with one overnight stay at 3,611 m. Medications were started 48 h before ascent (acetazolamide: n = 7, 250 mg 3 times/day; placebo: n = 6, 3 times/day). ...
Thirteen healthy, nonacclimatized lowlanders with a history of HAPE ascended (<22 h) from 1,130 to 4,559 m with one overnight stay …
Asymmetric and symmetric dimethylarginine in high altitude pulmonary hypertension (HAPH) and high altitude pulmonary edema (HAPE).
Hannemann J, Freytag J, Schiefer LM, Macholz F, Sareban M, Schmidt-Hutten L, Stang H, Schwedhelm E, Swenson ER, Böger R, Berger MM. Hannemann J, et al. Front Physiol. 2023 Nov 29;14:1297636. doi: 10.3389/fphys.2023.1297636. eCollection 2023. Front Physiol. 2023. PMID: 38093907 Free PMC article.
Fifty (study A) and thirteen (study B) non-acclimatized lowlanders were exposed to 4,559 m for 44 and 67 h, respectively. In contrast to study A, the participants in study B were characterized by a history of at least one episode of HAPE. ...
Fifty (study A) and thirteen (study B) non-acclimatized lowlanders were exposed to 4,559 m for 44 and 67 h, respectively. In contrast …
Endurance Athletes Are at Increased Risk for Early Acute Mountain Sickness at 3450 m.
Sareban M, Schiefer LM, Macholz F, Schäfer L, Zangl Q, Inama F, Reich B, Mayr B, Schmidt P, Hartl A, Bärtsch P, Niebauer J, Treff G, Berger MM. Sareban M, et al. Med Sci Sports Exerc. 2020 May;52(5):1109-1115. doi: 10.1249/MSS.0000000000002232. Med Sci Sports Exerc. 2020. PMID: 31876668 Clinical Trial.

METHODS: In 38 healthy, nonacclimatized men (19 ET and 19 untrained controls [UT], V O2max 66 6 mL.min.kg vs 45 7 mL.min.kg; P < 0.001) peripheral oxygen saturation (SpO2), heart rate variability, RMR, and poikilocapnic HVR were assessed at 424 m and during 48 h at

METHODS: In 38 healthy, nonacclimatized men (19 ET and 19 untrained controls [UT], V O2max 66 6 mL.min.kg vs 45 7 mL.min.kg; P < 0.00

Serum neurofilament level increases after ascent to 4559 m but is not related to acute mountain sickness.
Sareban M, Berger MM, Pinter D, Buchmann A, Macholz F, Schmidt P, Schiefer L, Schimke M, Niebauer J, Steinacker JM, Treff G, Khalil M. Sareban M, et al. Eur J Neurol. 2021 Mar;28(3):1004-1008. doi: 10.1111/ene.14606. Epub 2020 Nov 26. Eur J Neurol. 2021. PMID: 33095952 Free PMC article.
Neither at low altitude (p = 0.706) nor at high altitude (p = 0.985) was there a difference in sNfL between participants with and without AMS as measured 3 days after rapid ascent and 44 h of high-altitude exposure. Altitude sNfL did not correlate with AMS-C, either overal …
Neither at low altitude (p = 0.706) nor at high altitude (p = 0.985) was there a difference in sNfL between participants with and without AM …
Preserved right ventricular function but increased right atrial contractile demand in altitude-induced pulmonary hypertension.
Sareban M, Perz T, Macholz F, Reich B, Schmidt P, Fried S, Mairbäurl H, Berger MM, Niebauer J. Sareban M, et al. Int J Cardiovasc Imaging. 2020 Jun;36(6):1069-1076. doi: 10.1007/s10554-020-01803-x. Epub 2020 Mar 9. Int J Cardiovasc Imaging. 2020. PMID: 32152809 Free PMC article.

METHODS: Fifty healthy volunteers actively ascended from 1130 to 4559 m in < 22 h. All participants underwent 2D echocardiography during baseline examination at low altitude (424 m) and at three study time-points (7, 20 and 44 h) after arrival at high altitude. .

METHODS: Fifty healthy volunteers actively ascended from 1130 to 4559 m in < 22 h. All participants underwent 2D echocardiography

Validity of Four Consumer-Grade Optical Heart Rate Sensors for Assessing Volume and Intensity Distribution of Physical Activity.
Neudorfer M, Kumar D, Smeddinck JD, Kulnik ST, Niebauer J, Treff G, Sareban M. Neudorfer M, et al. Scand J Med Sci Sports. 2024 Nov;34(11):e14756. doi: 10.1111/sms.14756. Scand J Med Sci Sports. 2024. PMID: 39508366 Clinical Trial.
Validity of HR data measured with four consumer-grade optical sensors, the wrist-worn Garmin Venu 2S and Polar Vantage M2, and the upper arm-worn Polar Verity Sense and Scosche Rhythm24 were assessed in 32 participants over 24 h including various laboratory-based and free- …
Validity of HR data measured with four consumer-grade optical sensors, the wrist-worn Garmin Venu 2S and Polar Vantage M2, and the upper arm …
Reliability of echocardiographic speckle-tracking derived bi-atrial strain assessment under different hemodynamic conditions.
Sareban M, Perz T, Macholz F, Reich B, Schmidt P, Fried S, Mairbäurl H, Berger MM, Niebauer J. Sareban M, et al. Int J Cardiovasc Imaging. 2017 Nov;33(11):1685-1692. doi: 10.1007/s10554-017-1154-7. Epub 2017 May 12. Int J Cardiovasc Imaging. 2017. PMID: 28500377 Free PMC article.
Twenty healthy subjects underwent transthoracic echocardiography during a baseline examination at low-altitude (424 m) as well as 7, 20 and 44 h after arrival at high-altitude (4559 m). Atrial strain indices (i.e. reservoir, conduit and contractile strain) were determined …
Twenty healthy subjects underwent transthoracic echocardiography during a baseline examination at low-altitude (424 m) as well as 7, 20 and …
14 results