Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1974 1
1984 1
1985 1
1986 1
1992 1
1994 3
1995 2
1996 3
1999 2
2000 2
2001 5
2002 3
2003 3
2004 2
2005 2
2006 4
2007 3
2008 3
2009 7
2010 5
2011 5
2012 9
2013 5
2014 4
2015 8
2016 8
2017 5
2018 5
2019 5
2020 6
2021 10
2022 10
2023 8
2024 4

Text availability

Article attribute

Article type

Publication date

Search Results

123 results

Results by year

Filters applied: . Clear all
The following term was ignored: %
Page 1
Poly(Ethylene Piperidinium)s for Anion Exchange Membranes.
Chen H, Bang KT, Tian Y, Hu C, Tao R, Yuan Y, Wang R, Shin DM, Shao M, Lee YM, Kim Y. Chen H, et al. Angew Chem Int Ed Engl. 2023 Sep 18;62(38):e202307690. doi: 10.1002/anie.202307690. Epub 2023 Aug 9. Angew Chem Int Ed Engl. 2023. PMID: 37524652
Jingfang Granule mitigates Coxsackievirus B3-induced myocardial damage by modulating mucolipin 1 expression.
Sun B, Lin L, Yao T, Yao J, Zhang G, Li Y, Li C. Sun B, et al. J Ethnopharmacol. 2024 Feb 10;320:117396. doi: 10.1016/j.jep.2023.117396. Epub 2023 Nov 10. J Ethnopharmacol. 2024. PMID: 37951374
MATERIALS AND METHODS: C57 BL/6JNifdc mice were divided randomly into several groups: control, model, Jingfang Granule groups (0.23, 0.46, and 0.69 g/20g, respectively), and a positive group (oseltamivir, 19.33 mg/kg). ...
MATERIALS AND METHODS: C57 BL/6JNifdc mice were divided randomly into several groups: control, model, Jingfang Granule groups (0.23, 0.46, a …
Roxadustat for CKD-related Anemia in Non-dialysis Patients.
Coyne DW, Roger SD, Shin SK, Kim SG, Cadena AA, Moustafa MA, Chan TM, Besarab A, Chou W, Bradley C, Eyassu M, Leong R, Lee TT, Saikali KG, Szczech L, Yu KP. Coyne DW, et al. Kidney Int Rep. 2020 Dec 5;6(3):624-635. doi: 10.1016/j.ekir.2020.11.034. eCollection 2021 Mar. Kidney Int Rep. 2020. PMID: 33732977 Free PMC article.
Intraarterial catheter diameter and dynamic response of arterial pressure monitoring system: a randomized controlled trial.
Oh H, Choe SH, Kim YJ, Yoon HK, Lee HC, Park HP. Oh H, et al. J Clin Monit Comput. 2022 Apr;36(2):387-395. doi: 10.1007/s10877-021-00663-7. Epub 2021 Feb 1. J Clin Monit Comput. 2022. PMID: 33527182 Clinical Trial.
Adequate DR was observed more frequently in the 22G and 24G groups than the 20G group (13.7% and 15.4% vs. 4.2%, P = 0.011 and 0.004, respectively). The frequency of underdamped DR was higher in the 20G group than the 24G group (86.6% vs. 69.2%, P = 0.001), whereas …
Adequate DR was observed more frequently in the 22G and 24G groups than the 20G group (13.7% and 15.4% vs. 4.2%, P = 0.011 and 0.004, …
Analysis of flow rate and pressure in syringe-based wound irrigation using Bernoulli's equation.
Lee H, Lee YK, Park JY, Han JW. Lee H, et al. Sci Rep. 2022 Sep 2;12(1):14957. doi: 10.1038/s41598-022-19402-2. Sci Rep. 2022. PMID: 36056149 Free PMC article.
In order to maintain the pressure of 8-15 psi when nurses perform syringe-based irrigation, it is necessary to set the flow rate of the cleaning solution from 3.5 cc/s to less than 4.8 cc/s for 19G. In addition, 20G maintains the flow rate of the solution at 2.6 cc/s or mo …
In order to maintain the pressure of 8-15 psi when nurses perform syringe-based irrigation, it is necessary to set the flow rate of the clea …
123 results