Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2014 1
2015 1
2016 1
2018 1
2024 1

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

4 results

Results by year

Filters applied: . Clear all
Page 1
Did you mean M. haghpanah (6 results)?
Cylindrical agar gel with fluid flow subjected to an alternating magnetic field during hyperthermia.
Javidi M, Heydari M, Attar MM, Haghpanahi M, Karimi A, Navidbakhsh M, Amanpour S. Javidi M, et al. Int J Hyperthermia. 2015 Feb;31(1):33-9. doi: 10.3109/02656736.2014.988661. Epub 2014 Dec 19. Int J Hyperthermia. 2015. PMID: 25523967 Free article.
Fe3O4 as a nano-fluid was injected into the centre of a gel cylinder which was filled with another gel cylinder and subjected to an alternating magnetic field of 7.3 kA/m and a frequency of 50 kHz for 3600 s. The temperature was measured at three points in the gel. ...
Fe3O4 as a nano-fluid was injected into the centre of a gel cylinder which was filled with another gel cylinder and subjected to an alternat …
Effect of heat dissipation of superparamagnetic nanoparticles in alternating magnetic field on three human cancer cell lines in magnetic fluid hyperthermia.
Attar MM, Haghpanahi M. Attar MM, et al. Electromagn Biol Med. 2016;35(4):305-20. doi: 10.3109/15368378.2015.1089409. Epub 2016 Mar 25. Electromagn Biol Med. 2016. PMID: 27015154
Based on the experiments, it was observed that magnetic field with intensity of 8 kA/m within the frequency range of 80-180 kHz did not have any effect on the cells. CONCLUSIONS: Based on the results, it can be concluded that the nanoparticle dose of 80 g/ml with diameter …
Based on the experiments, it was observed that magnetic field with intensity of 8 kA/m within the frequency range of 80-180 kHz did n …
A finite element study on intra-operative corrective forces and evaluation of screw density in scoliosis surgeries.
Musapoor A, Nikkhoo M, Haghpanahi M. Musapoor A, et al. Proc Inst Mech Eng H. 2018 Dec;232(12):1245-1254. doi: 10.1177/0954411918810707. Epub 2018 Nov 19. Proc Inst Mech Eng H. 2018. PMID: 30453829
The results showed that the maximum estimated correction force and moment were 173 (55.43) N and 10.67 (2.02) N m, respectively, which were aligned with measured clinical observations. The sensitivity analysis on the magnitude of applied force to the screws showed that cor …
The results showed that the maximum estimated correction force and moment were 173 (55.43) N and 10.67 (2.02) N m, respectively, whic …