Lactose and sucrose aqueous solutions for high-dose dosimetry with 10-MeV electron beam irradiation

Radiat Prot Dosimetry. 2012 May;149(4):357-62. doi: 10.1093/rpd/ncr309. Epub 2011 Jul 15.

Abstract

In the present study, dosimetric characterisation of aqueous solutions of lactose and sucrose was analysed by UV spectrometry following irradiation using 10-MeV electron beam at doses between 0.5 and 10.5 kGy. As a dosimetric index, absorbance is selected at 256 and 264 nm for lactose and sucrose aqueous solutions, respectively. The intensity of absorbance for irradiated solutions depends on the pre-irradiation concentration of lactose and sucrose. The post-irradiation stability of both solutions was investigated at room temperature for a measurement period of 22 d.

MeSH terms

  • Dose-Response Relationship, Radiation
  • Electrons*
  • Lactose / chemistry*
  • Lactose / radiation effects
  • Radiation Monitoring / methods*
  • Solutions / chemistry
  • Spectrophotometry, Ultraviolet
  • Sucrose / chemistry*
  • Sucrose / radiation effects
  • Water / chemistry

Substances

  • Solutions
  • Water
  • Sucrose
  • Lactose