Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1976 1
1980 2
1981 2
1982 1
1983 3
1984 6
1985 2
1986 5
1987 5
1988 1
1989 1
1990 2
1991 1
1992 1
1993 1
1994 5
1995 2
1996 5
1997 5
1998 7
1999 6
2000 4
2001 3
2002 1
2003 2
2004 2
2005 1
2006 3
2007 3
2008 5
2009 5
2010 5
2011 6
2012 8
2013 9
2014 13
2015 14
2016 13
2017 7
2018 10
2019 12
2020 15
2021 23
2022 24
2023 35
2024 30
2025 8

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

278 results

Results by year

Filters applied: . Clear all
Page 1
Pulsed electric field, cryoballoon, and radiofrequency for paroxysmal atrial fibrillation ablation: a propensity score-matched comparison.
Della Rocca DG, Marcon L, Magnocavallo M, Menè R, Pannone L, Mohanty S, Sousonis V, Sorgente A, Almorad A, Bisignani A, Głowniak A, Del Monte A, Bala G, Polselli M, Mouram S, La Fazia VF, Ströker E, Gianni C, Zeriouh S, Bianchi S, Sieira J, Combes S, Sarkozy A, Rossi P, Boveda S, Natale A, de Asmundis C, Chierchia GB; HRMC Investigators. Della Rocca DG, et al. Europace. 2023 Dec 28;26(1):euae016. doi: 10.1093/europace/euae016. Europace. 2023. PMID: 38245007 Free PMC article.
Left ventricular functional recovery after atrial fibrillation catheter ablation in heart failure: a prediction model.
Bergonti M, Ascione C, Marcon L, Pambrun T, Della Rocca DG, Ferrero TG, Pannone L, Kühne M, Compagnucci P, Bonomi A, Gevaert AB, Anselmino M, Casella M, Krisai P, Tondo C, Rodríguez-Mañero M, Derval N, Chierchia GB, de Asmundis C, Heidbuchel H, Jaïs P, Sarkozy A. Bergonti M, et al. Eur Heart J. 2023 Sep 14;44(35):3327-3335. doi: 10.1093/eurheartj/ehad428. Eur Heart J. 2023. PMID: 37387689 Free article.
Acute Kidney Injury Resulting From Hemoglobinuria After Pulsed-Field Ablation in Atrial Fibrillation: Is it Preventable?
Mohanty S, Casella M, Compagnucci P, Torlapati PG, Della Rocca DG, La Fazia VM, Gianni C, Chierchia GB, MacDonald B, Mayedo A, Khan UN, Allison J, Bassiouny M, Gallinghouse GJ, Burkhardt JD, Horton R, Al-Ahmad A, Di Biase L, de Asmundis C, Russo AD, Natale A. Mohanty S, et al. JACC Clin Electrophysiol. 2024 Apr;10(4):709-715. doi: 10.1016/j.jacep.2023.12.008. Epub 2024 Feb 1. JACC Clin Electrophysiol. 2024. PMID: 38310489

Of those 21 patients, 4 (19%) had S-Cr. >2.5 mg/dL (mean: 2.95 0.21 mg/dL). The mean number of PF applications was significantly higher in those 4 patients than in the other 17 patients experiencing hemoglobinuria (94.63 3.20 vs 46.75 9.10, P < 0.001). In group 2 pat

Of those 21 patients, 4 (19%) had S-Cr. >2.5 mg/dL (mean: 2.95 0.21 mg/dL). The mean number of PF applications was significantly h …
Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study.
Ekanem E, Neuzil P, Reichlin T, Kautzner J, van der Voort P, Jais P, Chierchia GB, Bulava A, Blaauw Y, Skala T, Fiala M, Duytschaever M, Szeplaki G, Schmidt B, Massoullie G, Neven K, Thomas O, Vijgen J, Gandjbakhch E, Scherr D, Johannessen A, Keane D, Boveda S, Maury P, García-Bolao I, Anic A, Hansen PS, Raczka F, Lepillier A, Guyomar Y, Gupta D, Van Opstal J, Defaye P, Sticherling C, Sommer P, Kucera P, Osca J, Tabrizi F, Roux A, Gramlich M, Bianchi S, Adragão P, Solimene F, Tondo C, Russo AD, Schreieck J, Luik A, Rana O, Frommeyer G, Anselme F, Kreis I, Rosso R, Metzner A, Geller L, Baldinger SH, Ferrero A, Willems S, Goette A, Mellor G, Mathew S, Szumowski L, Tilz R, Iacopino S, Jacobsen PK, George A, Osmancik P, Spitzer S, Balasubramaniam R, Parwani AS, Deneke T, Glowniak A, Rossillo A, Pürerfellner H, Duncker D, Reil P, Arentz T, Steven D, Olalla JJ, de Jong JSSG, Wakili R, Abbey S, Timo G, Asso A, Wong T, Pierre B, Ewertsen NC, Bergau L, Lozano-Granero C, Rivero M, Breitenstein A, Inkovaara J, Fareh S, Latcu DG, Linz D, Müller P, Ramos-Maqueda J, Beiert T, Themistoclakis S, Meininghaus DG, Stix G, Tzeis S, Baran J, Almroth H, Munoz DR, de Sousa J, Efremidis M, Balsam P, Petr… See abstract for full author list ➔ Ekanem E, et al. Nat Med. 2024 Jul;30(7):2020-2029. doi: 10.1038/s41591-024-03114-3. Epub 2024 Jul 8. Nat Med. 2024. PMID: 38977913 Free PMC article.
On children's variable success with scalar inferences: Insights from disjunction in the scope of a universal quantifier.
Pagliarini E, Bill C, Romoli J, Tieu L, Crain S. Pagliarini E, et al. Cognition. 2018 Sep;178:178-192. doi: 10.1016/j.cognition.2018.04.020. Epub 2018 Jun 4. Cognition. 2018. PMID: 29879554
Previous developmental studies have revealed variation in children's ability to compute scalar inferences. While children have been shown to struggle with standard scalar inferences (e.g., with scalar quantifiers like "some") (Chierchia, Crain, Guasti, Gualmini, &am …
Previous developmental studies have revealed variation in children's ability to compute scalar inferences. While children have been s …
Characterization and Clinical Significance of Hemolysis After Pulsed Field Ablation for Atrial Fibrillation: Results of a Multicenter Analysis.
Popa MA, Venier S, Menè R, Della Rocca DG, Sacher F, Derval N, Hocini M, Dulucq S, Caluori G, Combes S, Albenque JP, Saitta F, Haller B, Chierchia GB, de Asmundis C, Defaye P, Boveda S, Jaïs P. Popa MA, et al. Circ Arrhythm Electrophysiol. 2024 Oct;17(10):e012732. doi: 10.1161/CIRCEP.124.012732. Epub 2024 Aug 30. Circ Arrhythm Electrophysiol. 2024. PMID: 39212069 Free article.
Focal Pulsed Field Ablation for Premature Ventricular Contractions: A Multicenter Experience.
Della Rocca DG, Cespón-Fernández M, Keelani A, Raffa S, Pannone L, Almorad A, Ströker E, Borisov G, Bala G, Sieira J, Vetta G, Alothman O, Sorgente A, Audiat C, Overeinder I, Frommhold M, Del Monte A, La Meir M, Natale A, Chierchia GB, Geller JC, de Asmundis C, Sarkozy A; HRMC Investigators. Della Rocca DG, et al. Circ Arrhythm Electrophysiol. 2024 Sep;17(9):e012826. doi: 10.1161/CIRCEP.124.012826. Epub 2024 Sep 5. Circ Arrhythm Electrophysiol. 2024. PMID: 39234745 Free article.
Energy output and the number of applications were left to the operator's discretion. RESULTS: Eleven (55%) procedures were conducted under general anesthesia, 6 (30%) under deep sedation, and 3 (15%) under light sedation. ...
Energy output and the number of applications were left to the operator's discretion. RESULTS: Eleven (55%) procedures were conducted …
Multielectrode catheter-based pulsed field ablation of persistent and long-standing persistent atrial fibrillation.
Della Rocca DG, Sorgente A, Pannone L, Cespón-Fernández M, Vetta G, Almorad A, Bala G, Del Monte A, Ströker E, Sieira J, Doundoulakis I, Mouram S, Audiat C, Monaco C, Mohanty S, Scacciavillani R, Marcon L, Nakasone K, Zaher W, Overeinder I, Boveda S, La Meir M, Natale A, Sarkozy A, de Asmundis C, Chierchia GB. Della Rocca DG, et al. Europace. 2024 Oct 3;26(10):euae246. doi: 10.1093/europace/euae246. Europace. 2024. PMID: 39351961 Free PMC article.
278 results