[Application of the inspiratory impedance threshold device and its research progress].
Wang C, Zhang G, Wu W, Wu T. Wang C, et al. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2014 Apr;31(2):452-7. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2014. PMID: 25039158 Review. Chinese.
The inspiratory impedance threshold device (ITD) was put forward by Lurie in 1995, and was assigned as a class II a recommendation by the International Liaison Committee on Resuscitation (ILCOR) resuscitation guidelines in 2005. ...
The inspiratory impedance threshold device (ITD) was put forward by Lurie in 1995, and was assigned as a class I …
Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest.
Aufderheide TP, Pirrallo RG, Provo TA, Lurie KG. Aufderheide TP, et al. Crit Care Med. 2005 Apr;33(4):734-40. doi: 10.1097/01.ccm.0000155909.09061.12. Crit Care Med. 2005. PMID: 15818098 Clinical Trial.
Statistical analyses performed included the chi-square test and multivariate regression analysis. One hundred sixteen patients were treated with a sham impedance threshold device, and 114 patients were treated with an active impedance threshold
Statistical analyses performed included the chi-square test and multivariate regression analysis. One hundred sixteen patients were treated …
Treatment of hypotension in pigs with an inspiratory impedance threshold device: a feasibility study.
Lurie KG, Zielinski TM, McKnite SH, Idris AH, Yannopoulos D, Raedler CM, Sigurdsson G, Benditt DG, Voelckel WG. Lurie KG, et al. Crit Care Med. 2004 Jul;32(7):1555-62. doi: 10.1097/01.ccm.0000131207.29081.a2. Crit Care Med. 2004. PMID: 15241102
Four separate experimental protocols were performed: protocol A, in which the hemodynamics of seven pigs were examined during application of an impedance threshold device at various levels of inspiratory impedance (-5, -10, -15, and -20 cm H(2)O …
Four separate experimental protocols were performed: protocol A, in which the hemodynamics of seven pigs were examined during application of …
Cardiopulmonary effects of a new inspiratory impedance threshold device in acute hemorrhagic shock in dogs.
Vigani A, Shih AC, Buckley GJ, Londoño L, Bandt C. Vigani A, et al. J Vet Emerg Crit Care (San Antonio). 2011 Dec;21(6):618-24. doi: 10.1111/j.1476-4431.2011.00692.x. Epub 2011 Nov 22. J Vet Emerg Crit Care (San Antonio). 2011. PMID: 22316254 Clinical Trial.
OBJECTIVE: To compare cardiovascular and respiratory effects of an inspiratory impedance threshold device (ITD) in dogs before and after induction of acute hemorrhagic shock. ...
OBJECTIVE: To compare cardiovascular and respiratory effects of an inspiratory impedance threshold device (ITD) …
Effect of an inspiratory impedance threshold device on hemodynamics during conventional manual cardiopulmonary resuscitation.
Pirrallo RG, Aufderheide TP, Provo TA, Lurie KG. Pirrallo RG, et al. Resuscitation. 2005 Jul;66(1):13-20. doi: 10.1016/j.resuscitation.2004.12.027. Resuscitation. 2005. PMID: 15993724 Clinical Trial.
BACKGROUND: In animals in cardiac arrest, an inspiratory impedance threshold device (ITD) has been shown to improve hemodynamics and neurologically intact survival. ...Diastolic BPs at T = 0, 2, 5 and 7 min were 20+/-12, 21+/-13, 23+/-15 and 25+/-14 in …
BACKGROUND: In animals in cardiac arrest, an inspiratory impedance threshold device (ITD) has been shown to impr …
Combination of active compression decompression cardiopulmonary resuscitation and the inspiratory impedance threshold device: state of the art.
Frascone RJ, Bitz D, Lurie K. Frascone RJ, et al. Curr Opin Crit Care. 2004 Jun;10(3):193-201. doi: 10.1097/01.ccx.0000126089.40242.a9. Curr Opin Crit Care. 2004. PMID: 15166836 Review.
PURPOSE OF REVIEW: Over the past decade, the combination of active compression decompression (ACD) cardiopulmonary resuscitation (CPR) and an impedance threshold device (ITD) has been shown to significantly increase vital organ perfusion pressures and surviva …
PURPOSE OF REVIEW: Over the past decade, the combination of active compression decompression (ACD) cardiopulmonary resuscitation (CPR) and a …
Effects of an inspiratory impedance threshold device on blood pressure and short term survival in spontaneously breathing hypovolemic pigs.
Sigurdsson G, Yannopoulos D, McKnite SH, Sondeen JL, Benditt DG, Lurie KG. Sigurdsson G, et al. Resuscitation. 2006 Mar;68(3):399-404. doi: 10.1016/j.resuscitation.2005.07.015. Epub 2006 Feb 7. Resuscitation. 2006. PMID: 16455176
BACKGROUND: The inspiratory impedance threshold device (ITD) has been shown to improve hemodynamic variables and survival outcomes during cardiopulmonary resuscitation in animals and humans. ...RESULTS: Treatment with the ITD resulted in lower intratra …
BACKGROUND: The inspiratory impedance threshold device (ITD) has been shown to improve hemodynamic variables and …
Use of an inspiratory impedance threshold device on a facemask and endotracheal tube to reduce intrathoracic pressures during the decompression phase of active compression-decompression cardiopulmonary resuscitation.
Plaisance P, Soleil C, Lurie KG, Vicaut E, Ducros L, Payen D. Plaisance P, et al. Crit Care Med. 2005 May;33(5):990-4. doi: 10.1097/01.ccm.0000163235.18990.f6. Crit Care Med. 2005. PMID: 15891326 Clinical Trial.
INTRODUCTION: Use of an inspiratory impedance threshold device (ITD) significantly increases coronary perfusion pressures and survival in patients ventilated with an endotracheal tube (ETT) during active compression-decompression cardiopulmonary resusc …
INTRODUCTION: Use of an inspiratory impedance threshold device (ITD) significantly increases coronary perfusion …
Inspiratory impedance threshold device effects on hypotension in heat-stroked swine.
Voelckel WG, Yannopoulos D, Zielinski T, McKnite S, Lurie KG. Voelckel WG, et al. Aviat Space Environ Med. 2008 Aug;79(8):743-8. doi: 10.3357/asem.2289.2008. Aviat Space Environ Med. 2008. PMID: 18717111
In heat stroke, hypotension is caused by relative central hypovolemia. We performed a feasibility study to determine if an inspiratory impedance threshold valve (ITDTM) set to open at -12 cm H2O would reverse systemic hypotension by enhancing venous return in …
In heat stroke, hypotension is caused by relative central hypovolemia. We performed a feasibility study to determine if an inspiratory
Hemodynamics associated with breathing through an inspiratory impedance threshold device in human volunteers.
Convertino VA, Ratliff DA, Ryan KL, Doerr DF, Ludwig DA, Muniz GW, Britton DL, Clah SD, Fernald KB, Ruiz AF, Lurie KG, Idris AH. Convertino VA, et al. Crit Care Med. 2004 Sep;32(9 Suppl):S381-6. doi: 10.1097/01.ccm.0000134348.69165.15. Crit Care Med. 2004. PMID: 15508665 Clinical Trial.
OBJECTIVE: Increased negative intrathoracic pressure during spontaneous inspiration through an impedance threshold device (ITD) causes elevated arterial blood pressure in humans. ...INTERVENTIONS: We measured hemodynamic and respiratory responses during two s …
OBJECTIVE: Increased negative intrathoracic pressure during spontaneous inspiration through an impedance threshold device