Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1860 1
1951 1
1992 2
1993 1
1994 4
1995 1
1996 1
1997 7
1998 1
1999 5
2000 1
2001 4
2002 4
2003 3
2004 5
2005 6
2006 7
2007 14
2008 7
2009 7
2010 4
2011 4
2012 4
2013 5
2014 6
2015 2
2016 2
2017 1
2018 2
2019 2
2020 0
Text availability
Article attribute
Article type
Publication date

Similar Articles for PMID: 12063226

99 results
Results by year
Filters applied: . Clear all
Page 1
Histopathologic findings in human cerebral aneurysms embolized with platinum coils: report of two cases and review of the literature.
Ishihara S, Mawad ME, Ogata K, Suzuki C, Tsuzuki N, Katoh H, Ohnuki A, Miyazawa T, Nawashiro H, Kaji T, Shima K. Ishihara S, et al. AJNR Am J Neuroradiol. 2002 Jun-Jul;23(6):970-4. AJNR Am J Neuroradiol. 2002. PMID: 12063226 Free article. Review.
Embolization of intracranial aneurysms with hydrogel-coated coils versus inert platinum coils: effects on packing density, coil length and quantity, procedure performance, cost, length of hospital stay, and durability of therapy.
Gaba RC, Ansari SA, Roy SS, Marden FA, Viana MA, Malisch TW. Gaba RC, et al. Stroke. 2006 Jun;37(6):1443-50. doi: 10.1161/01.STR.0000221314.55144.0b. Epub 2006 May 4. Stroke. 2006. PMID: 16675742
Endovascular treatment of experimental aneurysms by use of fibroblast-coated platinum coils: an angiographic and histopathologic study.
Dai D, Ding YH, Danielson MA, Kadirvel R, Hunter LW, Zhan WZ, Helm GA, Lewis DA, Cloft HJ, Sieck GC, Kallmes DF. Dai D, et al. Stroke. 2007 Jan;38(1):170-6. doi: 10.1161/01.STR.0000252128.83405.71. Epub 2006 Nov 22. Stroke. 2007. PMID: 17122421
Bare, bio-active and hydrogel-coated coils for endovascular treatment of experimentally induced aneurysms. Long-term histological and scanning electron microscopy results.
Reinges MH, Krings T, Drexler AY, Ludolph A, Sellhaus B, Bovi M, Geibprasert S, Agid R, Scherer K, Hans FJ. Reinges MH, et al. Interv Neuroradiol. 2010 Jun;16(2):139-50. doi: 10.1177/159101991001600205. Epub 2010 Jul 19. Interv Neuroradiol. 2010. PMID: 20642888 Free PMC article.
Endovascular treatment of experimental aneurysms by use of biologically modified embolic devices: coil-mediated intraaneurysmal delivery of fibroblast tissue allografts.
Marx WE, Cloft HJ, Helm GA, Short JG, Do HM, Jensen ME, Kallmes DE. Marx WE, et al. AJNR Am J Neuroradiol. 2001 Feb;22(2):323-33. AJNR Am J Neuroradiol. 2001. PMID: 11156778 Free article.
Ion implantation and protein coating of detachable coils for endovascular treatment of cerebral aneurysms: concepts and preliminary results in swine models.
Murayama Y, Viñuela F, Suzuki Y, Do HM, Massoud TF, Guglielmi G, Ji C, Iwaki M, Kusakabe M, Kamio M, Abe T. Murayama Y, et al. Neurosurgery. 1997 Jun;40(6):1233-43; discussion 1243-4. doi: 10.1097/00006123-199706000-00024. Neurosurgery. 1997. PMID: 9179897
Occlusion of neck remnant in experimental rat aneurysms after treatment with platinum- or polyglycolic-polylactic acid-coated coils.
Marjamaa J, Tulamo R, Frösen J, Abo-Ramadan U, Hernesniemi JA, Niemelä MR, Kangasniemi M. Marjamaa J, et al. Surg Neurol. 2009 Apr;71(4):458-65; discussion 465. doi: 10.1016/j.surneu.2007.12.026. Epub 2008 Jul 9. Surg Neurol. 2009. PMID: 18617246
99 results
Jump to page
Feedback