Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1994 1
1996 1
1999 1
2000 1
2002 2
2003 1
2004 1
2005 2
2006 4
2007 6
2008 3
2009 2
2010 3
2011 9
2012 5
2013 4
2014 2
2015 5
2016 4
2017 2
2019 1
2020 4
2021 0
Text availability
Article attribute
Article type
Publication date

Similar articles for PMID: 17494650

55 results
Results by year
Filters applied: . Clear all
Page 1
Stent conformity in curved vascular models with simulated aneurysm necks using flat-panel CT: an in vitro study.
Ebrahimi N, Claus B, Lee CY, Biondi A, Benndorf G. Ebrahimi N, et al. AJNR Am J Neuroradiol. 2007 May;28(5):823-9. AJNR Am J Neuroradiol. 2007. PMID: 17494650 Free article.
Study of conformability of the new leo plus stent to a curved vascular model using flat-panel detector computed tomography (DynaCT).
Valdivia y Alvarado M, Ebrahimi N, Benndorf G. Valdivia y Alvarado M, et al. Neurosurgery. 2009 Mar;64(3 Suppl):ons130-4; discussion ons134. doi: 10.1227/01.NEU.0000336304.26756.21. Neurosurgery. 2009. PMID: 19240562
Increased cell opening and prolapse of struts of a neuroform stent in curved vasculature: value of angiographic computed tomography: technical case report.
Benndorf G, Claus B, Strother CM, Chang L, Klucznik RP. Benndorf G, et al. Neurosurgery. 2006 Apr;58(4 Suppl 2):ONS-E380; discussion ONS-E380. doi: 10.1227/01.NEU.0000205287.06739.E1. Neurosurgery. 2006. PMID: 16575290
Spatial resolution limits of multislice computed tomography (MS-CT), C-arm-CT, and flat panel-CT (FP-CT) compared to MicroCT for visualization of a small metallic stent.
Ionescu M, Metcalfe RW, Cody D, Alvarado MV, Hipp J, Benndorf G. Ionescu M, et al. Acad Radiol. 2011 Jul;18(7):866-75. doi: 10.1016/j.acra.2011.02.012. Acad Radiol. 2011. PMID: 21669352
An in vitro study of silk stent morphology.
Aurboonyawat T, Blanc R, Schmidt P, Piotin M, Spelle L, Nakib A, Moret J. Aurboonyawat T, et al. Neuroradiology. 2011 Sep;53(9):659-67. doi: 10.1007/s00234-010-0784-4. Epub 2010 Oct 28. Neuroradiology. 2011. PMID: 20981414
Wall shear stress in intracranial self-expanding stents studied using ultra-high-resolution 3D reconstructions.
Benndorf G, Ionescu M, Y Alvarado MV, Hipp J, Metcalfe R. Benndorf G, et al. AJNR Am J Neuroradiol. 2009 Mar;30(3):479-86. doi: 10.3174/ajnr.A1396. Epub 2008 Nov 27. AJNR Am J Neuroradiol. 2009. PMID: 19039050 Free PMC article.
Flat panel detector angiographic CT for stent-assisted coil embolization of broad-based cerebral aneurysms.
Richter G, Engelhorn T, Struffert T, Doelken M, Ganslandt O, Hornegger J, Kalender WA, Doerfler A. Richter G, et al. AJNR Am J Neuroradiol. 2007 Nov-Dec;28(10):1902-8. doi: 10.3174/ajnr.A0697. Epub 2007 Sep 24. AJNR Am J Neuroradiol. 2007. PMID: 17893214 Free article.
Influence of different reconstruction parameters in the visualization of intracranial stents using C-arm flat panel CT angiography: experience in an animal model.
Ott S, Struffert T, Saake M, Gölitz P, Adamek E, Doerfler A. Ott S, et al. Acta Radiol. 2016 Feb;57(2):233-40. doi: 10.1177/0284185115571988. Epub 2015 Feb 22. Acta Radiol. 2016. PMID: 25711233
Deployment technique that takes advantage of the characteristics of Enterprise VRD2: an in vitro study.
Chihara H, Ishii A, Kikuchi T, Ikeda H, Arai D, Miyamoto S. Chihara H, et al. J Neurointerv Surg. 2017 Oct;9(10):969-973. doi: 10.1136/neurintsurg-2016-012400. Epub 2016 Aug 31. J Neurointerv Surg. 2017. PMID: 27581043
In vitro experiments of vessel wall apposition between the Enterprise and Enterprise 2 stents for treatment of cerebral aneurysms.
Kono K, Terada T. Kono K, et al. Acta Neurochir (Wien). 2016 Feb;158(2):241-5. doi: 10.1007/s00701-015-2666-3. Epub 2015 Dec 19. Acta Neurochir (Wien). 2016. PMID: 26687376
55 results
You have reached the last page of results. A maximum of 10,000 results are available.
Jump to page
Feedback