Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
My NCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1947 1
1963 1
1976 1
1977 1
1978 1
1980 1
1981 1
1984 2
1986 1
1987 3
1988 4
1989 2
1993 2
1994 3
1995 1
1996 2
1997 4
1998 1
1999 3
2000 1
2001 1
2002 6
2003 1
2004 6
2005 9
2006 7
2007 1
2008 7
2009 11
2010 13
2011 17
2012 25
2013 39
2014 39
2015 38
2016 58
2017 45
2018 42
2019 43
2020 20
Text availability
Article attribute
Article type
Publication date

Similar Articles for PMID: 23868162

389 results
Results by year
Filters applied: . Clear all
Page 1
Cerebral aneurysms treated with flow-diverting stents: computational models with intravascular blood flow measurements.
Levitt MR, McGah PM, Aliseda A, Mourad PD, Nerva JD, Vaidya SS, Morton RP, Ghodke BV, Kim LJ. Levitt MR, et al. AJNR Am J Neuroradiol. 2014 Jan;35(1):143-8. doi: 10.3174/ajnr.A3624. Epub 2013 Jul 18. AJNR Am J Neuroradiol. 2014. PMID: 23868162 Free PMC article.
Computational hemodynamics analysis of intracranial aneurysms treated with flow diverters: correlation with clinical outcomes.
Chong W, Zhang Y, Qian Y, Lai L, Parker G, Mitchell K. Chong W, et al. AJNR Am J Neuroradiol. 2014 Jan;35(1):136-42. doi: 10.3174/ajnr.A3790. Epub 2013 Nov 28. AJNR Am J Neuroradiol. 2014. PMID: 24287091 Free article.
How do coil configuration and packing density influence intra-aneurysmal hemodynamics?
Morales HG, Kim M, Vivas EE, Villa-Uriol MC, Larrabide I, Sola T, Guimaraens L, Frangi AF. Morales HG, et al. AJNR Am J Neuroradiol. 2011 Nov-Dec;32(10):1935-41. doi: 10.3174/ajnr.A2635. Epub 2011 Sep 1. AJNR Am J Neuroradiol. 2011. PMID: 21885712 Free article.
Comparison of two stents in modifying cerebral aneurysm hemodynamics.
Kim M, Taulbee DB, Tremmel M, Meng H. Kim M, et al. Ann Biomed Eng. 2008 May;36(5):726-41. doi: 10.1007/s10439-008-9449-4. Epub 2008 Feb 9. Ann Biomed Eng. 2008. PMID: 18264766 Free PMC article.
Intra-aneurysmal flow patterns and wall shear stresses calculated with computational flow dynamics in an anterior communicating artery aneurysm depend on knowledge of patient-specific inflow rates.
Karmonik C, Yen C, Grossman RG, Klucznik R, Benndorf G. Karmonik C, et al. Acta Neurochir (Wien). 2009 May;151(5):479-85; discussion 485. doi: 10.1007/s00701-009-0247-z. Epub 2009 Apr 3. Acta Neurochir (Wien). 2009. PMID: 19343271
Intra-aneurysmal hemodynamic alterations by a self-expandable intracranial stent and flow diversion stent: high intra-aneurysmal pressure remains regardless of flow velocity reduction.
Shobayashi Y, Tateshima S, Kakizaki R, Sudo R, Tanishita K, Viñuela F. Shobayashi Y, et al. J Neurointerv Surg. 2013 Nov;5 Suppl 3:iii38-42. doi: 10.1136/neurintsurg-2012-010488. Epub 2012 Oct 9. J Neurointerv Surg. 2013. PMID: 23048176
Accuracy of computational cerebral aneurysm hemodynamics using patient-specific endovascular measurements.
McGah PM, Levitt MR, Barbour MC, Morton RP, Nerva JD, Mourad PD, Ghodke BV, Hallam DK, Sekhar LN, Kim LJ, Aliseda A. McGah PM, et al. Ann Biomed Eng. 2014 Mar;42(3):503-14. doi: 10.1007/s10439-013-0930-3. Epub 2013 Oct 26. Ann Biomed Eng. 2014. PMID: 24162859 Free PMC article. Clinical Trial.
Angular remodeling in single stent-assisted coiling displaces and attenuates the flow impingement zone at the neck of intracranial bifurcation aneurysms.
Gao B, Baharoglu MI, Malek AM. Gao B, et al. Neurosurgery. 2013 May;72(5):739-48; discussion 748. doi: 10.1227/NEU.0b013e318286fab3. Neurosurgery. 2013. PMID: 23328687 Clinical Trial.
389 results
Jump to page
Feedback