Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My Custom Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1950 1
1952 1
1955 1
1959 1
1961 1
1963 5
1968 3
1970 1
1971 1
1972 2
1973 1
1975 1
1976 4
1977 2
1978 3
1979 4
1980 5
1981 8
1982 4
1983 9
1984 14
1985 7
1986 5
1987 6
1988 6
1989 10
1990 7
1991 7
1992 9
1993 9
1994 9
1995 9
1996 2
1997 7
1998 8
1999 10
2000 8
2001 9
2002 16
2003 11
2004 15
2005 12
2006 11
2007 7
2008 13
2009 8
2010 11
2011 7
2012 9
2013 17
2014 15
2015 15
2016 17
2017 14
2018 14
2019 13
2020 16
2021 13
2022 19
2023 12
2024 13
2025 3

Publication date

Text availability

Article attribute

Article type

Additional filters

Article Language

Species

Sex

Age

Other

Search Results

450 results

Results by year

Filters applied: . Clear all
Page 1
The determination of 2-phenylphenol in the presence of 4-chlorophenol using nano-Fe(3)O(4)/ionic liquid paste electrode as an electrochemical sensor.
Karimi-Maleh H, Fakude CT, Mabuba N, Peleyeju GM, Arotiba OA. Karimi-Maleh H, et al. J Colloid Interface Sci. 2019 Oct 15;554:603-610. doi: 10.1016/j.jcis.2019.07.047. Epub 2019 Jul 17. J Colloid Interface Sci. 2019. PMID: 31330427
A voltammetric sensor was fabricated for the determination of 2-phenylphenol (2-PP) as a water pollutant. The sensor was prepared by modifying carbon paste electrode (CPE) with a composite of Fe(3)O(4) nanoparticles (Fe(3)O(4)-NPs) and ionic liquid (n-hexyl-3-methyl …
A voltammetric sensor was fabricated for the determination of 2-phenylphenol (2-PP) as a water pollutant. The sensor was prepa …
All-in-one continuous electrochemical monitoring of 2-phenylphenol removal from water by electro-Fenton treatment.
Gomis-Berenguer A, Casanova A, Banks CE, Iniesta J. Gomis-Berenguer A, et al. Talanta. 2024 May 15;272:125761. doi: 10.1016/j.talanta.2024.125761. Epub 2024 Feb 15. Talanta. 2024. PMID: 38364564 Free article.
In this work, carbon black (CB) and oxidised carbon black (CBox) materials were investigated as cathodes in the electrochemical production of hydrogen peroxide involved in HEF reaction for the degradation of 2-phenylphenol (2PP) as a target pollutant. The electrodes …
In this work, carbon black (CB) and oxidised carbon black (CBox) materials were investigated as cathodes in the electrochemical production o …
Synthesis, characterization, biological activity and computation-based efficacy of cobalt(II) complexes of biphenyl-2-ol against SARS-CoV-2 virus.
Kumari S, Thakur M, Chauhan C, Kumari M. Kumari S, et al. J Biomol Struct Dyn. 2025 Jan;43(1):483-497. doi: 10.1080/07391102.2023.2283144. Epub 2023 Nov 21. J Biomol Struct Dyn. 2025. PMID: 37990487
Cobalt(II) complexes of biphenyl-2-ol of composition, CoCl(2-n)(OC(6)H(4)C(6)H(5)-2)(n)(H(2)O)(4) (where n = 1 or 2), were prepared by reacting cobaltous(II) chloride with equi- and bimolar ratios of sodium salt of biphenyl-2-ol. ...
Cobalt(II) complexes of biphenyl-2-ol of composition, CoCl(2-n)(OC(6)H(4)C(6)H(5)-2)(n)(H(2)O)(4) (where n = 1 or 2), w …
Evaluation of p-phenylenediamine, o-phenylphenol sodium salt, and 2,4-diaminotoluene in the rat comet assay as part of the Japanese Center for the Validation of Alternative Methods (JaCVAM)-initiated international validation study of in vivo rat alkaline comet assay.
De Boeck M, van der Leede BJ, De Vlieger K, Geys H, Vynckier A, Van Gompel J. De Boeck M, et al. Mutat Res Genet Toxicol Environ Mutagen. 2015 Jul;786-788:151-7. doi: 10.1016/j.mrgentox.2015.04.002. Epub 2015 Apr 7. Mutat Res Genet Toxicol Environ Mutagen. 2015. PMID: 26212306
As part of the Japanese Center for the Validation of Alternative Methods (JaCVAM)-initiated international validation study of in vivo rat alkaline comet assay (comet assay), p-phenylenediamine dihydrochloride (PPD), o-phenylphenol sodium salt (OPP), and 2,4-diaminot …
As part of the Japanese Center for the Validation of Alternative Methods (JaCVAM)-initiated international validation study of in vivo rat al …
Transformation of hydroxylated polychlorinated biphenyls by bacterial 2-hydroxybiphenyl 3-monooxygenase.
Suman J, Sredlova K, Fraraccio S, Jerabkova M, Strejcek M, Kabickova H, Cajthaml T, Uhlik O. Suman J, et al. Chemosphere. 2024 Feb;349:140909. doi: 10.1016/j.chemosphere.2023.140909. Epub 2023 Dec 7. Chemosphere. 2024. PMID: 38070605
In this study, we aimed to obtain a deeper insight into the transformation of OH-PCBs in soil bacteria and isolated a Pseudomonas sp. strain P1B16 based on its ability to use o-phenylphenol (2-PP) which, when exposed to the Delor 103-derived OH-PCB mixture, depleted …
In this study, we aimed to obtain a deeper insight into the transformation of OH-PCBs in soil bacteria and isolated a Pseudomonas sp. strain …
2-Hydroxypropyl-beta-cyclodextrin extracts 2-phenylphenol from silicone tubing.
den Brok MW, van der Schoot SC, Nuijen B, Hillebrand MJ, Beijnen JH. den Brok MW, et al. Int J Pharm. 2004 Jul 8;278(2):303-9. doi: 10.1016/j.ijpharm.2004.03.020. Int J Pharm. 2004. PMID: 15196635
In the present study, the potency of the commercially available and used cyclodextrin, 2-hydroxypropyl-beta-cyclodextrin (HPbetaCD) to extract the preservative 2-phenylphenol (2-PP) from platinum cured silicone tubing was tested. The presence of 2-PP was structurall …
In the present study, the potency of the commercially available and used cyclodextrin, 2-hydroxypropyl-beta-cyclodextrin (HPbetaCD) to extra …
450 results