Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

MyNCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1945 13
1946 70
1947 90
1948 130
1949 137
1950 230
1951 279
1952 296
1953 341
1954 373
1955 410
1956 336
1957 350
1958 331
1959 337
1960 398
1961 444
1962 549
1963 1108
1964 1725
1965 1141
1966 1288
1967 1676
1968 2142
1969 2528
1970 3009
1971 3281
1972 3368
1973 3889
1974 4136
1975 2670
1976 1782
1977 1891
1978 1702
1979 1855
1980 1802
1981 2076
1982 2308
1983 2511
1984 2608
1985 2915
1986 2921
1987 3044
1988 3339
1989 3989
1990 3975
1991 3997
1992 4283
1993 4335
1994 4223
1995 4587
1996 5015
1997 5605
1998 5609
1999 5641
2000 6305
2001 6173
2002 6479
2003 6793
2004 6828
2005 7591
2006 7775
2007 8275
2008 8911
2009 9114
2010 10223
2011 10629
2012 10481
2013 11012
2014 11245
2015 11526
2016 11358
2017 11353
2018 10731
2019 5341
2020 109
Text availability
Article attribute
Article type
Publication date

Search Results

278,319 results
Results by year
Filters applied: . Clear all
Page 1
Skin biopsy.
Veitch D, et al. Br J Hosp Med (Lond) 2018. PMID 29727224
Evolving biopsy techniques for the diagnosis of neuroblastoma in children.
Campagna G, et al. J Pediatr Surg 2018. PMID 29753525
BACKGROUND/PURPOSE: To compare the adequacy and safety of percutaneous core needle biopsy and surgical wedge biopsy of neuroblastoma in children. ...This can be considered as an alternative to open surgical biopsy. TYPE OF STUDY: Treatment Study. LEVEL OF EVIDENCE: III....
BACKGROUND/PURPOSE: To compare the adequacy and safety of percutaneous core needle biopsy and surgical wedge biopsy of neurobl …
Bovine Mammary Gland Biopsy Techniques.
Daley VL, et al. J Vis Exp 2018. PMID 30614491
Core and needle biopsy tools were used. The core biopsy tool was attached to a cordless drill and inserted into the MG tissue through the incision using a clock-wise drill action. ...Specific limitations may include bleeding after the biopsy and infection on the biopsy site. Applications of these techniques include tissue collection for clinical diagnosis and research purposes, such as primary cell culture....
Core and needle biopsy tools were used. The core biopsy tool was attached to a cordless drill and inserted into the MG tissue …
The evolving role of percutaneous biopsy in renal masses.
Garstka N, et al. Curr Opin Urol 2018 - Review. PMID 29847524
PURPOSE OF REVIEW: To review the current literature concerning the role of biopsy for renal masses. RECENT FINDINGS: Improvements in biopsy techniques lead to a redefinition of the role of renal mass biopsy (RMB).Additionally, several studies highlighted the safety, high diagnostic accuracy, and very low rate of clinically relevant complications of RMB. ...
PURPOSE OF REVIEW: To review the current literature concerning the role of biopsy for renal masses. RECENT FINDINGS: Improvements in …
European Federation of Neurological Societies/Peripheral Nerve Society Guideline on the use of skin biopsy in the diagnosis of small fiber neuropathy. Report of a joint task force of the European Federation of Neurological Societies and the Peripheral Nerve Society.
Lauria G, et al. Eur J Neurol 2010. PMID 20642627 Free article.
BACKGROUND: Revision of the guidelines on the use of skin biopsy in the diagnosis of peripheral neuropathy, published in 2005, has become appropriate owing to publication of more relevant articles. Most of the new studies focused on small fiber neuropathy (SFN), a subtype of neuropathy for which the diagnosis was first developed through skin biopsy examination. ...
BACKGROUND: Revision of the guidelines on the use of skin biopsy in the diagnosis of peripheral neuropathy, published in 2005, has be …
Stereotactic Biopsy Platforms with Intraoperative Imaging Guidance.
Mohyeldin A and Elder JB. Neurosurg Clin N Am 2017 - Review. PMID 28917276
We review frameless stereotactic biopsy platforms and focus on emerging technology integrating intraoperative MRI with frameless stereotaxy. Brain biopsy with iMRI allows for an accurate tissue sample with the ability to correct cannula trajectory during surgery, eliminating misdiagnosis secondary to faulty targeting. ...
We review frameless stereotactic biopsy platforms and focus on emerging technology integrating intraoperative MRI with frameless ster …
Transcutaneous pleural biopsy with a retrograde forceps: a novel approach.
Wiewiorski M, et al. Surg Endosc 2016. PMID 25894446
The surgeon performing the biopsy was blinded to the thoracoscopical view. After the removal of the forceps, it was checked whether biopsy material was retrieved. The video material was retrospectively used to confirm whether the biopsy was taken from the pleura parietalis. EVALUATION: Biopsy material was retrieved in 19 out of 20 biopsy attempts. ...
The surgeon performing the biopsy was blinded to the thoracoscopical view. After the removal of the forceps, it was checked whether …
Tumour seeding after fine-needle aspiration and core biopsy of the head and neck--a systematic review.
Shah KS and Ethunandan M. Br J Oral Maxillofac Surg 2016 - Review. PMID 26837638
Although fine-needle aspiration cytology (FNAC) and core needle biopsy are essential diagnostic investigations of lumps in the head and neck, seeding along the needle track has long been a concern, and various factors have been implicated. ...Seeding along the needle track after FNAC or core needle biopsy of a lump in the head and neck is rarely reported, and an accurate estimate of its incidence is difficult to ascertain. ...
Although fine-needle aspiration cytology (FNAC) and core needle biopsy are essential diagnostic investigations of lumps in the head a …
Repeated biopsy in the detection of prostate cancer: when and how many cores.
Scattoni V, et al. Arch Ital Urol Androl 2014 - Review. PMID 25641460 Free article.
The keywords were: prostate cancer, prostate biopsy, transrectal ultrasound, transperineal prostate biopsy. RESULTS: The recommended approach in repeated setting is still the extended scheme (EPBx) (12 cores). ...However, random PBx does not represent the approach of the future, but rather imaging targeted biopsy....
The keywords were: prostate cancer, prostate biopsy, transrectal ultrasound, transperineal prostate biopsy. RESULTS: The recom …
Transjugular liver biopsy.
Ble M, et al. Clin Liver Dis 2014 - Review. PMID 25438282
Liver biopsy is still the gold standard for evaluation of acute and chronic liver diseases, despite achievements regarding noninvasive diagnosis and staging in liver diseases. Transjugular liver biopsy (TJLB) has proved a good option when ascites and/or significant coagulopathy precludes a percutaneous approach. ...
Liver biopsy is still the gold standard for evaluation of acute and chronic liver diseases, despite achievements regarding noninvasiv …
278,319 results
Jump to page
Feedback