Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

MyNCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1947 1
1948 1
1951 15
1952 27
1953 5
1954 2
1955 16
1956 23
1957 14
1958 30
1959 48
1960 55
1961 43
1962 29
1963 1
1964 2
1965 36
1966 66
1967 102
1968 129
1969 128
1970 113
1971 158
1972 183
1973 157
1974 236
1975 277
1976 224
1977 270
1978 333
1979 350
1980 344
1981 392
1982 358
1983 384
1984 462
1985 647
1986 583
1987 604
1988 639
1989 715
1990 654
1991 628
1992 691
1993 672
1994 595
1995 651
1996 663
1997 576
1998 420
1999 423
2000 443
2001 496
2002 476
2003 462
2004 452
2005 430
2006 489
2007 488
2008 500
2009 518
2010 555
2011 645
2012 692
2013 798
2014 915
2015 902
2016 844
2017 777
2018 704
2019 335
2020 10
Text availability
Article attribute
Article type
Publication date

Search Results

24,726 results
Results by year
Filters applied: . Clear all
Page 1
Bone marrow edema.
Schett G. Ann N Y Acad Sci 2009 - Review. PMID 19250229
A bone marrow edema pattern on MRI has a similar signal quality as an inflamed synovium and may, in fact, reflect true inflammatory infiltrates rather than a pure accumulation of extracellular fluid. ...However, even without erosive change, periarticular bone marrow lesions may be seen. This chapter describes the nature of bone marrow lesions detected by MRI in patients with inflammatory arthritis....
A bone marrow edema pattern on MRI has a similar signal quality as an inflamed synovium and may, in fact, reflect true inflamm …
Bone marrow edema in sports: general concepts.
Vanhoenacker FM and Snoeckx A. Eur J Radiol 2007 - Review. PMID 17317067
MR imaging is the only imaging technique that allows direct evaluation of bone marrow edema in sports medicine. The use of fat suppressed T2-weighted or STIR images is particularly appropriate to detect bone marrow edema. The extent of bone marrow edema reflects the biomechanics of trauma. Compressive forces between two bony structures will result in extensive areas of bone marrow edema, whereas distraction forces provoke more subtle areas of bone marrow edema at the insertion of supporting structures of joints. ...
MR imaging is the only imaging technique that allows direct evaluation of bone marrow edema in sports medicine. The use of fat …
MRI of bone marrow abnormalities in hematological malignancies.
Silva JR, et al. Diagn Interv Radiol 2013 - Review. PMID 23748035 Free article.
Magnetic resonance imaging (MRI) is essential for evaluating bone marrow. Bone marrow undergoes constant modification and its appearance on MRI changes in response. ...This pictorial review describes the MRI pulse sequences used for imaging of bone marrow, and illustrates bone marrow changes due hematological malignancies, including changes following treatment....
Magnetic resonance imaging (MRI) is essential for evaluating bone marrow. Bone marrow undergoes constant modific …
Bone marrow biopsy and evaluation.
Grindem CB. Vet Clin North Am Small Anim Pract 1989 - Review. PMID 2672535
Bone marrow evaluation provides valuable diagnostic and prognostic information about neoplastic, metabolic, and inflammatory diseases. Bone marrow biopsies should be done only after examination of peripheral blood, to avoid performing unnecessary biopsies. A blood sample should be taken at the time of the bone marrow biopsy, for complete hematopoietic evaluation. ...
Bone marrow evaluation provides valuable diagnostic and prognostic information about neoplastic, metabolic, and inflammatory d
Histopathology of bone marrow.
Travlos GS. Toxicol Pathol 2006 - Review. PMID 17067944
As a major hematopoietic and lymphoid organ, morphological evaluation of the bone marrow is an important component of toxicity or safety assessment studies. While definitive characterization of bone marrow lesions often requires cytological aspirates or smears, assessment of histological bone marrow sections provides information regarding tissue architecture and hematopoietic status that is relevant for the detection of direct or indirect responses to chemical exposure. ...
As a major hematopoietic and lymphoid organ, morphological evaluation of the bone marrow is an important component of toxicity …
Dark t1 bone marrow.
Allen GM. Semin Musculoskelet Radiol 2011 - Review. PMID 21644198
Bone marrow contains fat and water. Using magnetic resonance (MR) T1-weighted images, fat appears light gray and water appears dark gray. ...Reactivation of bone marrow reduces the signal of fatty marrow. Additional sequences and supplementary imaging with conventional radiographs and computed tomography are often helpful in determining the nature of the low signal lesions. ...
Bone marrow contains fat and water. Using magnetic resonance (MR) T1-weighted images, fat appears light gray and water appears
[Myelodysplastic/myeloproliferative neoplasm: a histopathological review]
Kayano H. Rinsho Ketsueki 2018 - Review. PMID 30305512 Japanese.
There is ineffective erythropoiesis and bone marrow coexistence of at least one hematopoietic lineage morphologically characterized by dysplasia of blood cells and other (s) characterized by pronounced proliferation. ...
There is ineffective erythropoiesis and bone marrow coexistence of at least one hematopoietic lineage morphologically characte …
24,726 results
Jump to page
Feedback