Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1917 1
1924 1
1935 1
1946 3
1947 2
1948 6
1949 2
1953 4
1954 5
1955 3
1956 5
1958 3
1959 5
1960 5
1961 1
1962 1
1963 9
1964 9
1965 10
1966 13
1967 3
1968 7
1969 6
1970 12
1971 15
1972 3
1973 6
1974 9
1975 44
1976 50
1977 42
1978 42
1979 51
1980 77
1981 99
1982 133
1983 169
1984 230
1985 258
1986 348
1987 423
1988 519
1989 845
1990 970
1991 1227
1992 1385
1993 1460
1994 1795
1995 1946
1996 2086
1997 2535
1998 2651
1999 2878
2000 3357
2001 3681
2002 3915
2003 4454
2004 5614
2005 6152
2006 6951
2007 7811
2008 8475
2009 9479
2010 10766
2011 12560
2012 14947
2013 17975
2014 20406
2015 23017
2016 24230
2017 25730
2018 27498
2019 30355
2020 36684
2021 42614
2022 44007
2023 42098
2024 32539
2025 7

Text availability

Article attribute

Article type

Publication date

Search Results

427,268 results

Results by year

Filters applied: . Clear all
Page 1
Diagnostic Strategies for the Assessment of Suspected Stable Coronary Artery Disease : A Systematic Review and Meta-analysis.
Zito A, Galli M, Biondi-Zoccai G, Abbate A, Douglas PS, Princi G, D'Amario D, Aurigemma C, Romagnoli E, Trani C, Burzotta F. Zito A, et al. Ann Intern Med. 2023 Jun;176(6):817-826. doi: 10.7326/M23-0231. Epub 2023 Jun 6. Ann Intern Med. 2023. PMID: 37276592 Review.
Low-certainty evidence compared SPECT-MPI versus exercise ECG (2 trials), SPECT-MPI versus stress cardiovascular magnetic resonance imaging (1 trial), and stress echocardiography versus exercise ECG (1 trial). ...CONCLUSION: For the initial assessment …
Low-certainty evidence compared SPECT-MPI versus exercise ECG (2 trials), SPECT-MPI versus stress cardiovascular …
Flurpiridaz F-18 PET Myocardial Perfusion Imaging in Patients With Suspected Coronary Artery Disease.
Maddahi J, Agostini D, Bateman TM, Bax JJ, Beanlands RSB, Berman DS, Dorbala S, Garcia EV, Feldman J, Heller GV, Knuuti JM, Martinez-Clark P, Pelletier-Galarneau M, Shepple B, Tamaki N, Tranquart F, Udelson JE. Maddahi J, et al. J Am Coll Cardiol. 2023 Oct 17;82(16):1598-1610. doi: 10.1016/j.jacc.2023.08.016. J Am Coll Cardiol. 2023. PMID: 37821170 Clinical Trial.
Patients underwent 1-day rest/stress flurpiridaz PET and 1- or 2-day rest-stress Tc-99m-labeled single photon emission computed tomography (SPECT) before ICA. PET and SPECT images were read by 3 experts blinded to clinical and ICA data. ...CONCLUSIONS: This second f …
Patients underwent 1-day rest/stress flurpiridaz PET and 1- or 2-day rest-stress Tc-99m-labeled single photon emission computed tomography ( …
Diagnostic accuracy of dynamic CZT-SPECT in coronary artery disease. A systematic review and meta-analysis.
Panjer M, Dobrolinska M, Wagenaar NRL, Slart RHJA. Panjer M, et al. J Nucl Cardiol. 2022 Aug;29(4):1686-1697. doi: 10.1007/s12350-021-02721-8. Epub 2021 Aug 4. J Nucl Cardiol. 2022. PMID: 34350553 Free PMC article. Review.
CONCLUSION: Based on the results of the current systematic review and meta-analysis, dynamic CZT-SPECT MPI demonstrated a good sensitivity and specificity to diagnose CAD as compared to the gold standards. However, due to the heterogeneity of th …
CONCLUSION: Based on the results of the current systematic review and meta-analysis, dynamic CZT-SPECT MPI demon …
The performance of non-invasive tests to rule-in and rule-out significant coronary artery stenosis in patients with stable angina: a meta-analysis focused on post-test disease probability.
Knuuti J, Ballo H, Juarez-Orozco LE, Saraste A, Kolh P, Rutjes AWS, Jüni P, Windecker S, Bax JJ, Wijns W. Knuuti J, et al. Eur Heart J. 2018 Sep 14;39(35):3322-3330. doi: 10.1093/eurheartj/ehy267. Eur Heart J. 2018. PMID: 29850808 Free article.
AIMS: To determine the ranges of pre-test probability (PTP) of coronary artery disease (CAD) in which stress electrocardiogram (ECG), stress echocardiography, coronary computed tomography angiography (CCTA), single-photon emission computed tomography (SPECT), positr …
AIMS: To determine the ranges of pre-test probability (PTP) of coronary artery disease (CAD) in which stress electrocardiogram (ECG), …
Solid-State Detector SPECT Myocardial Perfusion Imaging.
Slomka PJ, Miller RJH, Hu LH, Germano G, Berman DS. Slomka PJ, et al. J Nucl Med. 2019 Sep;60(9):1194-1204. doi: 10.2967/jnumed.118.220657. Epub 2019 Aug 2. J Nucl Med. 2019. PMID: 31375568 Free article. Review.
Improved photon sensitivity has facilitated fast or low-dose myocardial perfusion imaging (MPI), and early dynamic imaging has emerged as a technique for assessing myocardial blood flow with SPECT. ...This review summarizes state-of-the-art solid-state SPECT
Improved photon sensitivity has facilitated fast or low-dose myocardial perfusion imaging (MPI), and early dynamic imaging has emerge …
Diagnostic Performance of CMR, SPECT, and PET Imaging for the Identification of Coronary Artery Disease: A Meta-Analysis.
Xu J, Cai F, Geng C, Wang Z, Tang X. Xu J, et al. Front Cardiovasc Med. 2021 May 7;8:621389. doi: 10.3389/fcvm.2021.621389. eCollection 2021. Front Cardiovasc Med. 2021. PMID: 34026862 Free PMC article.
The aim of this meta-analysis is to compare CMR, SPECT, and PET in the diagnosis of CAD and to provide evidence for further research and clinical decision-making. ...Results: A total of 203 articles were identified for inclusion in this meta- …
The aim of this meta-analysis is to compare CMR, SPECT, and PET in the diagnosis of CAD and to provide evidence …
Diagnostic analysis of new quantitative parameters of low-dose dynamic myocardial perfusion imaging with CZT SPECT in the detection of suspected or known coronary artery disease.
Pang Z, Wang J, Li S, Chen Y, Wang X, Li J. Pang Z, et al. Int J Cardiovasc Imaging. 2021 Jan;37(1):367-378. doi: 10.1007/s10554-020-01962-x. Epub 2020 Sep 10. Int J Cardiovasc Imaging. 2021. PMID: 32914404 Free PMC article.
The goal of this study is to explore and evaluate the diagnostic values of myocardial blood flow (MBF), myocardial flow reserve (MFR) and relative flow reserve (RFR) obtained with low-dose dynamic CZT SPECT for patients with suspected or known coronary artery disease (C
The goal of this study is to explore and evaluate the diagnostic values of myocardial blood flow (MBF), myocardial flow reserve (MFR) and re …
The "fixed" SPECT MPI defect: Where are we and where should we be going?
Gewirtz H. Gewirtz H. J Nucl Cardiol. 2021 Apr;28(2):730-734. doi: 10.1007/s12350-020-02434-4. Epub 2020 Nov 11. J Nucl Cardiol. 2021. PMID: 33175302
This brief review focuses on reasons why myocardial perfusion imaging (MPI) SPECT defects may appear "fixed" (rest vs stress). A combination of technical and physiology factors are responsible in most cases and are discussed. ...Emphasis is given to use of the actua …
This brief review focuses on reasons why myocardial perfusion imaging (MPI) SPECT defects may appear "fixed" (rest vs stress). …
Gender differences in the diagnostic accuracy of SPECT myocardial perfusion imaging: a bivariate meta-analysis.
Iskandar A, Limone B, Parker MW, Perugini A, Kim H, Jones C, Calamari B, Coleman CI, Heller GV. Iskandar A, et al. J Nucl Cardiol. 2013 Feb;20(1):53-63. doi: 10.1007/s12350-012-9646-2. Epub 2012 Nov 13. J Nucl Cardiol. 2013. PMID: 23149886
BACKGROUND: It remains controversial whether the diagnostic accuracy of single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI) is different in men as compared to women. We performed a meta-analysis to investigate gender dif …
BACKGROUND: It remains controversial whether the diagnostic accuracy of single-photon emission computed tomography myocardial perfusion imag …
427,268 results
You have reached the last available page of results. Please see the User Guide for more information.