The Technology of Processed Electroencephalogram Monitoring Devices for Assessment of Depth of Anesthesia
Fahy BG and Chau DF. Anesth Analg 2018 - Review. PMID 28786839
Advances in this field are evidenced by updated versions of existing monitors, development of new monitors, and increasing research unveiling the mechanisms of anesthesia on the brain. ...Also included is a table describing 10 available commercial depth-of-anesthesia monitors....
Advances in this field are evidenced by updated versions of existing monitors, development of new monitors, and increasing res …
Anaesthetic interventions for prevention of awareness during surgery
Messina AG, et al. Cochrane Database Syst Rev 2016 - Review. PMID 27755648 Free PMC article.
'Wakefulness' is when patients become conscious during surgery, but have no postoperative recollection of the period of consciousness. ...SELECTION CRITERIA: We included randomized controlled trials (RCTs) of either anaesthetic regimens or anaesthetic depth monitors. ...
'Wakefulness' is when patients become conscious during surgery, but have no postoperative recollection of the period of consciousness
BIS monitoring versus clinical assessment for sedation in mechanically ventilated adults in the intensive care unit and its impact on clinical outcomes and resource utilization
Shetty RM, et al. Cochrane Database Syst Rev 2018 - Review. PMID 29464690 Free PMC article.
Current practice is to use scales or scores to assess depth of sedation based on clinical criteria such as consciousness, understanding and response to commands. ...Bispectral index (BIS) monitors, which are based on the processing of electroencephalographic signals, may overcome the restraints of the sedation scales and provide a more reliable and consistent guidance for the titration of sedation depth.The benefits of BIS monitoring of patients under general anaesthesia for surgical procedures have already been confirmed by another Cochrane review. ...
Current practice is to use scales or scores to assess depth of sedation based on clinical criteria such as consciousness, understandi …
ECT: a new look at an old friend
Kadiyala PK and Kadiyala LD. Curr Opin Anaesthesiol 2018 - Review. PMID 29870425
Desflurane reduces intraoperative remifentanil requirements more than sevoflurane: comparison using surgical pleth index-guided analgesia
Ryu KH, et al. Br J Anaesth 2018 - Clinical Trial. PMID 30336856 Free article.
Further studies using other monitors with different measuring mechanisms are warranted to determine the cause of this difference. ...
Further studies using other monitors with different measuring mechanisms are warranted to determine the cause of this difference. ...