Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2001 2
2003 1
2004 1
2005 3
2006 2
2007 1
2008 2
2009 2
2010 11
2011 11
2012 17
2013 22
2014 21
2015 28
2016 44
2017 37
2018 30
2019 46
2020 33
2021 41
2022 50
2023 33
2024 10

Text availability

Article attribute

Article type

Publication date

Search Results

322 results

Results by year

Filters applied: . Clear all
The following term was ignored: "
Page 1
CZT camera systems may provide better risk stratification for low-risk patients.
Miller RJH, Han D, Rozanski A, Gransar H, Friedman JD, Hayes S, Thomson L, Tamarappoo B, Slomka PJ, Berman DS. Miller RJH, et al. J Nucl Cardiol. 2021 Dec;28(6):2927-2936. doi: 10.1007/s12350-020-02128-x. Epub 2020 Jun 4. J Nucl Cardiol. 2021. PMID: 32500175
Compared to SSS 0, minimal perfusion abnormality (SSS 1-3) was associated with increased all-cause mortality with CZT camera (adjusted HR 1.32, P = .017) and NaI camera (adjusted HR 1.29, P = .001, interaction P = .803). ...CONCLUSIONS: Increasing stress perf …
Compared to SSS 0, minimal perfusion abnormality (SSS 1-3) was associated with increased all-cause mortality with CZT camera ( …
Diagnostic accuracy for CZT gamma camera compared to conventional gamma camera technique with myocardial perfusion single-photon emission computed tomography: Assessment of myocardial infarction and function.
Hedeer F, Akil S, Oddstig J, Hindorf C, Arheden H, Carlsson M, Engblom H. Hedeer F, et al. J Nucl Cardiol. 2023 Oct;30(5):1935-1946. doi: 10.1007/s12350-022-03185-0. Epub 2023 Mar 13. J Nucl Cardiol. 2023. PMID: 36913172 Free PMC article.
BACKGROUND: The solid-state cadmium-zinc-telluride (CZT) gamma camera for myocardial perfusion single-photon emission computed tomography (MPS) has theoretical advantages compared to the conventional gamma camera technique. ...For LVEF, however, accuracy was …
BACKGROUND: The solid-state cadmium-zinc-telluride (CZT) gamma camera for myocardial perfusion single-photon emission computed …
CZT camera: moving beyond classical CAD detection?
Schindler TH. Schindler TH. Eur J Nucl Med Mol Imaging. 2015 Jun;42(7):991-3. doi: 10.1007/s00259-015-3033-6. Eur J Nucl Med Mol Imaging. 2015. PMID: 25801991 No abstract available.
A Pictorial Review of I-123 MIBG Imaging of Neuroblastoma Utilizing a State-of-the-Art CZT SPECT/CT System.
Sweet C, Shmuel N, Shoaf JN, Stoecklein M, Muthukrishnan A, Stern E, Nguyen NC. Sweet C, et al. Nucl Med Mol Imaging. 2024 Feb;58(1):1-8. doi: 10.1007/s13139-023-00825-2. Epub 2023 Sep 26. Nucl Med Mol Imaging. 2024. PMID: 38250182 Review.
On planar imaging, CZT shows greater image quality than at conventional gamma-camera using the Infinia Hawkeye (GE Healthcare). Physiologic structures such as salivary glands and myocardium show sharper borders with a more notable signal-to-noise ratio at CZT
On planar imaging, CZT shows greater image quality than at conventional gamma-camera using the Infinia Hawkeye (GE Healthcare) …
Prospective Paired Comparison of 123I-FP-CIT SPECT Images Obtained With a 360-CZT and a Conventional Camera.
Piatkova Y, Payoux P, Boursier C, Bordonne M, Roch V, Marie PY, Hossu G, Imbert L, Verger A. Piatkova Y, et al. Clin Nucl Med. 2022 Jan 1;47(1):14-20. doi: 10.1097/RLU.0000000000003969. Clin Nucl Med. 2022. PMID: 34874345
PURPOSE: This study aimed to compare 123I-FP-CIT SPECT imaging obtained from a 360 cadmium-zinc-telluride (CZT) camera with different focus configurations and from a conventional Anger camera. METHODS: This prospective study (NCT03980418) included patients re …
PURPOSE: This study aimed to compare 123I-FP-CIT SPECT imaging obtained from a 360 cadmium-zinc-telluride (CZT) camera with di …
Radiopharmaceutical imaging based on 3D-CZT Compton camera with 3D-printed mouse phantom.
Tian F, Geng C, Yao Z, Wu R, Xu J, Cai F, Tang X. Tian F, et al. Phys Med. 2022 Apr;96:140-148. doi: 10.1016/j.ejmp.2022.03.005. Epub 2022 Mar 11. Phys Med. 2022. PMID: 35287101
PURPOSE: The study proposes the use of three-dimensional CdZnTe Compton camera (3D-CZT CC) for radiopharmaceutical imaging and investigates the influence factors using a 3D-printed mouse phantom. ...RESULTS: Simulation results show that the intrinsic energy resoluti …
PURPOSE: The study proposes the use of three-dimensional CdZnTe Compton camera (3D-CZT CC) for radiopharmaceutical imaging and …
Performance study of a 360 CZT camera for monitoring (177)Lu-PSMA treatment.
Vergnaud L, Badel JN, Giraudet AL, Kryza D, Mognetti T, Baudier T, Rida H, Dieudonné A, Sarrut D. Vergnaud L, et al. EJNMMI Phys. 2023 Sep 22;10(1):58. doi: 10.1186/s40658-023-00576-1. EJNMMI Phys. 2023. PMID: 37736779 Free PMC article.
BACKGROUND: The aim of this study was to investigate the quantification performance of a 360 CZT camera for (177)Lu-based treatment monitoring. METHODS: Three phantoms with known (177)Lu activity concentrations were acquired: (1) a uniform cylindrical phantom for ca …
BACKGROUND: The aim of this study was to investigate the quantification performance of a 360 CZT camera for (177)Lu-based trea …
Characterisation of a hand-held CZT-based gamma camera for (177)Lu imaging.
Roth D, Larsson E, Sundlöv A, Sjögreen Gleisner K. Roth D, et al. EJNMMI Phys. 2020 Jul 8;7(1):46. doi: 10.1186/s40658-020-00313-y. EJNMMI Phys. 2020. PMID: 32642884 Free PMC article.
In this work, the suitability of a CZT-based hand-held camera for (177)Lu imaging is investigated. The energy response of CZT-based detectors combined with the multiple photon emissions of (177)Lu poses new challenges compared to (99m)Tc imaging, and a thorou …
In this work, the suitability of a CZT-based hand-held camera for (177)Lu imaging is investigated. The energy response of C
322 results