Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

MyNCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2009 5
2010 14
2011 93
2012 213
2013 214
2014 208
2015 157
2016 176
2017 151
2018 159
2019 73
2020 7
Text availability
Article attribute
Article type
Publication date

Search Results

1,195 results
Results by year
Filters applied: . Clear all
Page 1
Implant Abutment and Restoration Design and Risk Factors for Peri-Implant Disease.
Mahn DH. Compend Contin Educ Dent 2019. PMID 31573216
Abutment design elements that may affect the risk for developing peri-implantitis include topography, materials, height, implant-abutment connection, and emergence profile. This article discusses these implant abutment design elements for bone-level implants and the risks they may present for the development of peri-implant disease....
Abutment design elements that may affect the risk for developing peri-implantitis include topography, materials, height, im
The influence of implant-abutment connection to peri-implant bone loss: A systematic review and meta-analysis.
Caricasulo R, et al. Clin Implant Dent Relat Res 2018. PMID 29761902
PURPOSE: Different implant-abutment connections are available and it has been claimed they could have an effect on marginal bone loss. ...The search was conducted by using the Medical Subject Headings (MeSH) keywords "dental implants OR dental abutment AND external connection OR internal connection OR conical connection OR Morse Taper." ...
PURPOSE: Different implant-abutment connections are available and it has been claimed they could have an effect on marginal bo …
[Dental implant restoration abutment selection].
Bin S and Hao Z. Hua Xi Kou Qiang Yi Xue Za Zhi 2017. PMID 28682539 Chinese. Free article.
An increasing number of implant restoration abutment types are produced with the rapid development of dental implantology. Although various abutments can meet different clinical demands, the selection of the appropriate abutment is both difficult and confusing. This article aims to help clinicians select the appropriate abutment by describing abutment design, types, and selection criteria....
An increasing number of implant restoration abutment types are produced with the rapid development of dental implantolo …
The effective design of zirconia coping on titanium base in dental implant superstructure.
Mieda M, et al. Dent Mater J 2018. PMID 29081448 Free article.
To avoid abutment-fracture, the parts composed of zirconia with a bonded metal component connected to the implant can be used. ...To assess the strength of the abutment design, static loads were applied vertically and 30 degrees from the vertical axis. A test of tensile strength was also performed after chewing simulation. ...
To avoid abutment-fracture, the parts composed of zirconia with a bonded metal component connected to the implant can be used. …
Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System.
Sim BK, et al. J Healthc Eng 2017. PMID 29065610 Free PMC article.
The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. ...To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA) and mechanical test. ...
The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abu
Rational design and in vitro characterization of novel dental implant and abutment surfaces for balancing clinical and biological needs.
Milleret V, et al. Clin Implant Dent Relat Res 2019. PMID 30809940
BACKGROUND: Long-term success and patient satisfaction of dental implant systems can only be achieved by fulfilling clinical as well as biological needs related to maintenance, aesthetics, soft tissue sealing, and osseointegration, among others. ...PURPOSE: To decipher the clinical and biological needs in implant dentistry. To address identified needs, next-generation dental implant and abutment surfaces are designed and characterized in vitro. ...
BACKGROUND: Long-term success and patient satisfaction of dental implant systems can only be achieved by fulfilling clinical a …
Effect of Implant-Abutment Connection Type on Bone Around Dental Implants in Long-Term Observation: Internal Cone Versus Internal Hex.
Szyszkowski A and Kozakiewicz M. Implant Dent 2019. PMID 31188171
PURPOSE: The purpose of this study was to evaluate the influence of the implant-abutment connection type on the bone level around dental implants in long-term observation and the survival rate for the different types of implant-abutment connections. MATERIALS AND METHODS: Two groups of implants made of titanium grade 23 alloy and with sandblasted and acid-etched (SLA) surface were included in the study: (a) the internal hex implant-abutment connection group (480 SPI dental implants; Alpha-Bio Tec, Petach Tikwa, Israel, 184 patients) and (b) the internal cone implant-abutment connection group (60 C1 dental implants; MIS Implant Technologies, Shlomi, Israel, 34 patients). ...
PURPOSE: The purpose of this study was to evaluate the influence of the implant-abutment connection type on the bone level aro …
Comparison of external and internal implant-abutment connections for implant supported prostheses. A systematic review and meta-analysis.
Lemos CAA, et al. J Dent 2018. PMID 29221955
No significant difference was observed in implant survival (P=0.65; Risk Ratio (RR): 0.83; 95% CI: 0.38-1.84), and complication rates (P=0.43; RR: 1.15; 95% CI: 0.81-1.65). ...However, the implant-abutment connection had no influence on the implant's survival and complication rates. Based on the GRADE approach the evidence was classified as very low to moderate due to the study design, inconsistency, and publication bias. ...
No significant difference was observed in implant survival (P=0.65; Risk Ratio (RR): 0.83; 95% CI: 0.38-1.84), and complication rates …
Optimization of the Conical Angle Design in Conical Implant-Abutment Connections: A Pilot Study Based on the Finite Element Method.
Yao KT, et al. J Oral Implantol 2018. PMID 29090979
Conical implant-abutment connections are popular for their excellent connection stability, which is attributable to frictional resistance in the connection. ...Compared with the original design (5.7°), the optimal design demonstrated an increased rigidity of abutment (36.4%) and implant (25.5%), a decreased microgap at the implant-abutment interface (62.3%), a decreased contact pressure (37.9%) with a more uniform stress distribution in the connection, and a decreased stress in the cortical bone (4.5%). ...
Conical implant-abutment connections are popular for their excellent connection stability, which is attributable to frictional …
Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics
Najeeb S, et al. J Prosthodont Res 2016 - Review. PMID 26520679
STUDY SELECTION: An electronic search was carried out via the PubMed (Medline) database using keywords 'polyetheretherketone', 'dental' and 'dentistry' in combination. ...For example, PEEK dental implants have exhibited lesser stress shielding compared to titanium dental implants due to closer match of mechanical properties of PEEK and bone. ...
STUDY SELECTION: An electronic search was carried out via the PubMed (Medline) database using keywords 'polyetheretherketone', 'dental
1,195 results
Jump to page
Feedback