Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

MyNCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1947 1
1951 5
1952 6
1953 11
1954 9
1955 5
1956 7
1957 6
1958 5
1959 14
1960 16
1961 23
1962 17
1963 16
1964 26
1965 12
1966 4
1967 1
1968 1
1969 9
1970 17
1971 147
1972 353
1973 463
1974 446
1975 238
1976 129
1977 130
1978 138
1979 149
1980 147
1981 172
1982 152
1983 198
1984 198
1985 203
1986 235
1987 252
1988 261
1989 249
1990 357
1991 390
1992 354
1993 397
1994 375
1995 323
1996 282
1997 300
1998 318
1999 296
2000 322
2001 293
2002 286
2003 319
2004 372
2005 414
2006 573
2007 578
2008 572
2009 725
2010 518
2011 422
2012 447
2013 416
2014 470
2015 547
2016 436
2017 378
2018 328
2019 111
2020 3
Text availability
Article attribute
Article type
Publication date

Search Results

15,426 results
Results by year
Filters applied: . Clear all
Page 1
A Measurement Setup and Automated Calculation Method to Determine the Charge Injection Capacity of Implantable Microelectrodes.
Cisnal A, et al. Sensors (Basel) 2018. PMID 30486353 Free PMC article.
The design of safe stimulation protocols for functional electrostimulation requires knowledge of the "maximum reversible charge injection capacity" of the implantable microelectrodes. One of the main difficulties encountered in characterizing such microelectrodes is the calculation of the access voltage V(a). ...
The design of safe stimulation protocols for functional electrostimulation requires knowledge of the "maximum reversible charge injection ca …
All-Diamond Microelectrodes as Solid State Probes for Localized Electrochemical Sensing.
Silva EL, et al. Anal Chem 2015. PMID 26057348
This ME (microelectrode) assembly consists of an inner boron doped diamond (BDD) layer and an outer undoped diamond layer. Both layers were grown on a sharp tungsten tip by chemical vapor deposition (CVD) in a stepwise manner within a single deposition run. ...The applicability of the microelectrodes in localized corrosion was demonstrated by scanning amperometric measurements of oxygen distribution above an Al-Cu-CFRP (Carbon Fiber Reinforced Polymer) galvanic corrosion cell....
This ME (microelectrode) assembly consists of an inner boron doped diamond (BDD) layer and an outer undoped diamond layer. Both layer …
How to make calcium-sensitive microelectrodes.
Thomas RC and Bers DM. Cold Spring Harb Protoc 2013. PMID 23547154
Ca(2+)-sensitive microelectrodes (CaSMs) directly measure the pCa at their tip, which can be in a small extracellular space or inside a large and robust cell. ...
Ca(2+)-sensitive microelectrodes (CaSMs) directly measure the pCa at their tip, which can be in a small extracellular space or inside …
Recording and Modulation of Epileptiform Activity in Rodent Brain Slices Coupled to Microelectrode Arrays.
Panuccio G, et al. J Vis Exp 2018. PMID 29863681 Free PMC article.
Acute brain slices coupled to microelectrode arrays (MEAs) represent a valuable tool to study neuronal network interactions and their modulation by electrical stimulation. ...
Acute brain slices coupled to microelectrode arrays (MEAs) represent a valuable tool to study neuronal network interactions and their …
High-performance iridium oxide/platinum nano-leaf composite coatings on microelectrodes for neural stimulation/recording.
Qi Zeng , et al. Conf Proc IEEE Eng Med Biol Soc 2017. PMID 29060059
A novel platinum (Pt) nano-leaf interfacial layer between the Pt substrate and iridium oxide (IrO(x)) coating, significantly reduced impedance and increased cathodic charge storage capacity (CSC(c)) for neural microelectrodes. ...
A novel platinum (Pt) nano-leaf interfacial layer between the Pt substrate and iridium oxide (IrO(x)) coating, significantly reduced impedan …
15,426 results
Jump to page
Feedback