Skip to main page content
Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

MyNCBI Filters
Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1967 3
1968 3
1969 1
1970 1
1971 1
1972 3
1973 9
1974 27
1975 32
1976 34
1977 100
1978 193
1979 250
1980 254
1981 192
1982 212
1983 252
1984 265
1985 342
1986 353
1987 454
1988 434
1989 411
1990 530
1991 521
1992 602
1993 555
1994 493
1995 511
1996 496
1997 657
1998 779
1999 850
2000 964
2001 949
2002 1055
2003 1334
2004 1618
2005 1721
2006 1907
2007 2264
2008 2294
2009 2625
2010 2844
2011 3277
2012 3228
2013 3586
2014 3581
2015 3710
2016 3835
2017 3706
2018 3592
2019 1654
2020 37
Text availability
Article attribute
Article type
Publication date

Search Results

53,799 results
Results by year
Filters applied: . Clear all
Page 1
Wearables and the medical revolution
Dunn J, et al. Per Med 2018 - Review. PMID 30259801 Free article.
Wearable sensors are already impacting healthcare and medicine by enabling health monitoring outside of the clinic and prediction of health events. ...We cover applications in the following health areas: metabolic, cardiovascular and gastrointestinal monitoring; sleep, neurology, movement disorders and mental health; maternal, pre- and neo-natal care; and pulmonary health and environmental exposures. ...
Wearable sensors are already impacting healthcare and medicine by enabling health monitoring outside of the clinic and prediction of …
Ambulatory reflux monitoring for diagnosis of gastro-esophageal reflux disease: Update of the Porto consensus and recommendations from an international consensus group.
Roman S, et al. Neurogastroenterol Motil 2017 - Review. PMID 28370768
BACKGROUND: An international group of experts evaluated and revised recommendations for ambulatory reflux monitoring for the diagnosis of gastro-esophageal reflux disease (GERD). ...In this setting, testing can be either catheter-based or wireless pH-monitoring or pH-impedance monitoring. In patients with a high probability of GERD (esophagitis grade C and D, histology proven Barrett's mucosa >1 cm, peptic stricture, previous positive pH monitoring) and persistent symptoms, pH-impedance monitoring should be performed on treatment. ...
BACKGROUND: An international group of experts evaluated and revised recommendations for ambulatory reflux monitoring for the diagnosi …
Pressure Waveform Analysis
Jozwiak M, et al. Anesth Analg 2018 - Review. PMID 29077613
Perioperative hemodynamic monitoring is recommended for high-risk surgical patients since it reduces the number of complications in these patients. The pressure waveform analysis monitoring, especially with uncalibrated devices, is suitable for this purpose. In the intensive care setting, hemodynamic monitoring is recommended for patients with acute circulatory failure, who do not respond to initial therapy. ...
Perioperative hemodynamic monitoring is recommended for high-risk surgical patients since it reduces the number of complications in t …
Clinical Approach to Patients with Palpitations
Giada F and Raviele A. Card Electrophysiol Clin 2018 - Review. PMID 29784490
When the initial evaluation results are negative and the patient is suffering from heart disease, or if the palpitations are frequent or poorly tolerated and with a high probability of an arrhythmic origin, ambulatory electrocardiogram monitoring and/or electrophysiological study should be undertaken....
When the initial evaluation results are negative and the patient is suffering from heart disease, or if the palpitations are frequent or poo …
[Clinical application of the electric cardiometry based non-invasive ICON® hemodynamic monitor]
Zakariás D, et al. Orv Hetil 2018 - Review. PMID 30392409 Hungarian.
Establishment of a proper hemodynamic monitoring system in order to achieve optimal care among critically ill patients is fundamental. ...Our summary focuses on the ICON(®) patient monitoring system. This newly engineered, non-invasive tool is based on electrical cardiometry, and uses hemodynamic parameters in both neonatal and pediatric care as well as in adults. ...
Establishment of a proper hemodynamic monitoring system in order to achieve optimal care among critically ill patients is fundamental …
Adherence to medication and drug monitoring in apparent treatment-resistant hypertension.
Eskås PA, et al. Blood Press 2016 - Review. PMID 26729283
Methods for monitoring adherence are divided into indirect and direct methods. The indirect methods are mainly based on self-reported adherence and can easily be manipulated by the patient. ...Therapeutic drug monitoring and directly observed therapy with subsequent ambulatory blood pressure measurement are considered to be reliable methods and should be used more in the routine assessment of patients with apparent treatment-resistant hypertension....
Methods for monitoring adherence are divided into indirect and direct methods. The indirect methods are mainly based on self-reported …
Chronic heart failure management and remote haemodynamic monitoring.
Wolfson AM, et al. Heart 2018 - Review. PMID 30121633
A number of telemonitoring strategies exploring remote monitoring and management of clinical signs and symptoms of congestion in HF have had equivocal results. Early studies of remote haemodynamic monitoring showed promise, but issues with device integrity and implantation-associated adverse events hindered progress. ...
A number of telemonitoring strategies exploring remote monitoring and management of clinical signs and symptoms of congestion in HF h …
Remote Monitoring for Chronic Disease Management: Atrial Fibrillation and Heart Failure.
Ono M and Varma N. Card Electrophysiol Clin 2018 - Review. PMID 29428141
Remote monitoring is useful for early detection for device-detected atrial fibrillation, which increases the risk of thromboembolic events. ...Multiparameter monitoring with automatic transmission is useful for heart failure management. Improved adherence to remote monitoring and an optimal algorithm for transmitted alerts and their management are warranted in the management of heart failure....
Remote monitoring is useful for early detection for device-detected atrial fibrillation, which increases the risk of thromboembolic e …
53,799 results
Jump to page
Feedback